Maintenance
Do a check of the wheels.
Look for damage and bad
connections.
Clean the pre-filter.
Replace the pre-filter.
Replace the Hepa filter
To clean the dust extractor
It is important to clean the dust extractor to prevent
circulation of dangerous dust. Always clean the dust
extractor before it is moved from the work area.
WARNING:
its OFF position and disconnect the cord
from the wall outlet before you clean or do
maintenance to the product.
All equipment once used must be regarded as
contaminated and be treated thereafter.
All parts that are contaminated after service work
must be disposed in a correct procedure in plastic
bags. Refer to local regulations.
Use correct personal equipment when you clean the
Personal protective equipment on
product. Refer to
page 10 .
Clean the external surface with a moist cloth.
Clean the filters and the dust extractor in applicable
area.
Vacuum the pre-filter from the inside. Always use
dust extractors with Hepa filter and a soft brush to
not damage the filter.
Do not use water on electrical components.
Do not clean the dust extractor with high pressure
(air or water).
Do not put tools on the surface of the filter, it can
cause damage to the filter.
Do not make a hole in the Hepa filter, it can cause a
health risk.
Filter change
WARNING:
equipment, refer to
equipment on page 10 , during filter change.
Dust can come out during filter change.
WARNING:
switch in the Off position and disconnect the
cord from the wall outlet during filter change.
14
Before each
Daily
use
Turn the motor switch to
Use personal safety
Personal protective
Always turn the motor
Weekly
When suc-
tion is low
X
X
X
X
WARNING:
fasteners can cause damage to the operator
when assemble the product.
To clean the pre filter
The filter must be cleaned from time to time. This
must be done before changing the plastic bag collection
system and should also be done when work is
completed or when there is poor suction..
CAUTION:
items across the filter surface as this will
damage the filter.
CAUTION:
the filters.
1. While running the dust extractor, seal the inlet using
the inlet plug or the inlet valve.
2. Let the dust extractor build up vacuum for 5
seconds, then quickly push and hold down the Jet
Pulse handle for 5 seconds.
3. Repeat step 2 five times. It is important to let the
dust extractor rebuild the vacuum in between every
repetition.
4. If suction remains poor, the filter should be replaced.
Only replace plastic bag after cleaning the filter.
The pre filter
Only use Pullman Ermator filters. Performance and
filtration efficiency can only be assured with original
filters.
WARNING:
tube. If one is broken, it is necessary to
replace the complete filter.
To change the pre filter
1. Loosen the 2 toggle fasteners between the tank and
the lower cyclone.
2. Loosen the 2 toggle fasteners at the hose
connection between the tank and the Hepa filter
cover.
6 months or
12 months
1000h
or 2000h
X
X
Be careful, the toggle
Avoid hitting or dragging
Do not use water to clean
Do not replace only one
966 - 003 - 11.04.2022