Model
Distri-
bution
box
T10000
YES
480V
T18000
YES
480V
Pullman Ermator T-Line Dust Extractor are supplied with
Hubbell inlets and receptacles.
Part no
Hubbell part no
A
HBL4100R9W
B
HBL4100B9W
C
CS8175
D
CS8169
E
HBL7774WO
F
HBL460B7W
G
HBL460R7W
H
CS8375
Before use
WARNING:
extractor make sure that the power and
voltage corresponds with the voltage shown
on the machines rating plate, including
extension cords.
WARNING:
grounded outlet only. Refer to
instructions on page 12
Grounding instructions
WARNING:
be grounded. If it should malfunction or
breakdown, grounding provides a path
of least resistance for electric current to
reduce the risk of electric shock. The dust
extractor is equipped with a cord having
an equipment-grounding conductor and
grounding plug. The plug must be inserted
into an appropriate outlet that is properly
12
A
B
C
1
Standard
IEC 60309
IEC 60309
®
Twistlock
®
Twistlock
®
Twistlock
IEC 60309
IEC60309
®
Twistlock
Before using the dust
Connect to a properly
Grounding
The dust extractor must
D
E
1
1
Description
FEMALE RECEPTACLE, 100A, 3-PHASE, 250V, 4 Wire.
INLET MALE, 100A, 3-PHASE, 250V 4 Wire.
INLET MALE, 50A, 3-PHASE, 480V, 4 Wire, Grounding.
RECEPTACLE FEMALE, 50A. 3-PHASE, 480V, 4 Wire,
Grounding.
Well plate
INLET MALE, 60A, 3-PHASE, 480V, 4 Wire
RECEPTABLE FEMALE, 60A, 480V, 3-PHASE, 4 Wire.
INLET MALE, 50A, 3-PHASE, 250V, 4 Wire.
Operation
installed and grounded in accordance with
all local codes and ordinances.
To start and stop
Push the green button (A) to start the dust extractor.
Push the red button (B) to stop the dust extractor.
A
Phase converter
Note:
Not applicable to variants sold in Australia or
New Zealand.
F
G
H
1
1
B
966 - 003 - 11.04.2022