Télécharger Imprimer la page

Cebora SYNSTAR 270 T SRS Manuel D'instructions page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
• Inductance correction.
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
Adjust the value by turning knob 2.
To confirm the selection, press knob 2 or key
Press the DEF key to restore factory settings.
• Torch trigger.
The selection is between Mode 2T, Mode 4T and
Mode 3L.
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
To select mode, turn knob 2. To confirm the selection,
press knob 2 or key
Spot.
The operator can choose between Spot time and in-
termittent function.
This function is blocked when function 3L is activated.
If you select spot time when ON, the screen displays
the function spot time. While selecting it you can
adjust it by means of the adjustment bar.
In addition to spot time, the display shows the pause
time. When this is selected, use the adjustment bar to
regulate the pause time between one welding spot or
section and another.
Turn knob 2 to select the parameter and confirm the
selection by pressing the same knob.
Adjust the value by turning knob 2. To confirm the se-
lection press knob 2 or key
Press the DEF key to restore factory settings.
.
.
• HSA (Automatic Hot Start).
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
If you select HSA when ON the screen displays the
start current, current time and connection time. To
.
adjust these parameters see chapter on Start Mode.
Press the DEF key to restore factory settings.
• CRA, (final crater filling).
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
If you select CRA when ON the screen displays the
connection time, crater filling current and crater
filling time. To adjust these parameters see chapter
on Start Mode.
Press the DEF key to restore factory settings.
• Soft Start.
Adjustment ranges from 0 to 100%. This is the wire
speed expressed as a percentage of the speed set for
welding, before the wire touches the workpiece to be
welded.
This adjustment is important for consistently achieving
effective start-up.
The manufacturer adjustment is Auto (Default fun-
ction)
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
Adjust the value by turning knob 2 Confirm the choice
by pressing knob 2 or key
Press the DEF key to restore factory settings.
• Burnback Correction.
Adjustment ranges from -9.9 to +9.9%. Its purpose is
to adjust the length of the wire coming out of the gas
nozzle after welding. A positive figure corresponds to
more wire burnt.
The manufacturer's setting is 0 (Default function).
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
.
23

Publicité

loading

Ce manuel est également adapté pour:

564