8.2
Pump
Servicing the pump and pressure pipe
NOTICE
Disconnect system from energy sources!
Ensure that the electrical components are dis-
connected from the electrical power supply dur-
ing the work.
Open the cover plate.
Open the quick-release closure on the pump.
Pull out the pump, complete with pressure pipe, by the
handle.
Check the pump parts for deformation and deposits, con-
tact KESSEL service department if necessary.
Ensure the moving parts can move easily.
Carry out a visual check of the fitting components.
Wipe the float switch down with a damp cloth.