Switch 3 - Sample Rate Conversion, No Sample
Rate Conversion
Set switch 3 to OFF to enable sample rate conversion, or
ON to disable sample rate conversion. This switch should
almost always be set to OFF to ensure audio is embedded
at the correct sample rate for television.
When switch 3 is set to OFF this setting converts the sample
rate of your analog or AES/EBU audio and embeds audio
into the SDI output at a sample rate of 48 kHz.
Switch 2 - Ch 2 or AES/EBU 3+4 Embed / Bypass
Once you have selected your audio channels, use switches
2 and 1 to select which channels to embed or disable. The
disable setting lets you avoid overwriting audio channels
you wish to keep in the audio signal.
Set switch 2 to ON to bypass channel 2, or AES/EBU
channels 3 and 4. Set switch 1 to ON to bypass channel 1,
or AES/EBU channels 1 and 2.
Switch 1 - Ch 1 or AES/EBU 1+2 Embed/Bypass
See switch 2 description.
Audio Selection Tables
Input Audio Source
XLR Analog
XLR AES/EBU
Rca Analog
Optical
SDI Channel Tables
Analog Audio Channels
1-2
3-4
5-6
7-8
9-10
The switch legend on the base of your converter gives you
all the information you need to change conversion settings.
Switch 8
OFF
OFF
ON
ON
Switch 6
Switch 5
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
31
Switch 7
Switch Diagram
OFF
ON
OFF
ON
Switch 4
Switch Diagram
OFF
ON
OFF
ON
OFF