G
B
After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various START, RADIO, OPEN and CLOSE
buttons.
By activating the START, OPEN or CLOSE button the gate does not move.
ACCESSORIES -
For the connections and the technical data of the optional equipments follow the relevant handbooks.
PLATE TO BE CEMENTED
RADIO TRANSMITTER SUN
SUN 2CH
cod. ACG6052
SUN CLONE 2CH
cod. ACG6056
SUN-PRO 2CH
cod. ACG6210
SUN-PROX 2CH
cod. ACG6220
FAULT
code ACG8103
SUN 4CH
cod. ACG6054
SUN CLONE 4CH
cod. ACG6058
SUN-PRO 4CH
cod. ACG6214
SUN-PROX 4CH
cod. ACG6224
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to B.I.O.
input.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF. => Fix or replace the
faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
MODULE 6 RACK
with CATAPHORESIS treatment, right angle in 2 m - 6,56 feet bars.
RADIO MODULE 433MHz
code ACG8069
38
SOLUTION
code ACS9090