carry out jumper between COM A+ and EDGE 1/EDGE 2)
LED DL13 (BLUE)
ON
Some functions are enabled via smartphone, so via
smartphone check the card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (full stroke programming)
Dip 2>1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Dip 1 > 3 - transmitter code programming for pedestrian opening
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm from Self-learning failed
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
10 seconds tone with 2 seconds pause
BUZZER STATUS
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
6 Tones every 5 seconds
(It is renewed by giving a command)
Continuous tone for 10 seconds with
2-second pause.
Not active when DIP 2 in OFF
37
FLASHER STATUS
Off
Off
Off
Off
Off
Off
Off
FLASHER STATUS
Off
Off
Off
Off
Off
Off
Off
Off
1 Tone
Off
1 Tone
Off
Off
Off
Off
Off
2 Tones
Off
FLASHER STATUS
Off
Off
1 Tone
Off
2 Tones
Off
Off
Off
Enabled for 1 minute
Off
Off
Off
Off
Off
Off
Off
DL1 LED STATUS
Flashes on-off 250 ms
Flashes on-off 500 ms
Flashes on-off 500 ms
On steady
DL12 LED STATUS
Flashes intermittently red/green
Flashes red for 10 seconds
Flashes green for 10 seconds
Flashes orange for 10 seconds
Turns green once
Turns red once
Turns red once
Runs 6 green flashes
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
Led DL6 turns off
Led DL7-8 turns off
Led DL9-10 turns off
Led DL1 flashes on-off 250 ms
No led combined
No led combined
Led DL12 is steady on green.
No leds matched
Blue led flashes once every 5 seconds
No leds matched
G
B