A - CONNEXIONS
IT IS COMPULSORY TO SET THE
DIP 13 OF THE CONTROL PANEL
IN THE ON POSITION.
T1
T2
JC
JC
JB
JA
POWER
230 VAC
J1
L1 - N
230 Vac 50/60Hz power supply (120Vac 60Hz upon request)
J2
Flashing light (max 40W )
U
Motor common connection
V-W
Motor phases and capacitor connections
J3
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Gate open state (24 Vdc 3 W max)
COM A+
Common contacts / Positive 24 Vdc
J4
A+ COM
+ 24Vdc accessories power supply / Common contacts
A-
- 24Vdc accessories power supply
A+ TEST
+ 24Vdc photocells self-test power supply
J5
COM A+
Common contacts / Positive 24 Vdc
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
J6
COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOT 1
Photocells contact 1 (NC)
PHOT 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
J7
COM A+
Common contacts / Positive 24 Vdc
LIMIT SWITCH
Limit switches that cuts off the motor
J8
PROBE
IS NOT AVAILABLE
J9
ENCODER
IS NOT AVAILABLE
J8
J7
J6
J5
J4
J3
J2
J1
F1
MOTOR
CAPACITOR
J10
J11
J12
J13
J14
J15
J16
J17
F1
CARD R2
T1 - T2 T
JA
JB
JC
33
RS485 termination of J11
APP+
Connector for APP+ card
APP
Connector for APP card
SERIAL COM /
Connector for serial connection
SYNC
-
-
RADIO
Connector for radio module ACG8069
RADIO
Connector for radio receiver RIB, 24 Vdc supply
433 MHz Radio antenna
PROG.
Programming button
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL11 LED OFF)
LOW SP
IS NOT AVAILABLE
TORQUE
IS NOT AVAILABLE
T5A
Fuse for motor protection
POWER RELAYS FOR THE COMMAND OF THE MOTOR
R-N
SINGLE PHASE POWER SUPPLY - NEUTRAL
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
L1-N
SINGLE PHASE POWER SUPPLY FOR THE L1 CONTROL PANEL
TO BE DONE BY THE MANUFACTURER
X-Y-Z
CONNECTION TO THE POWER RELAYS, TO BE DONE BY
THE MANUFACTURER
G
B
PROG
J11
J12
J13
J14
J15
J16
J17

Publicité

loading