G
B
POINT B - SETTINGS
DIP 1
MAINTENANCE CHECK (See Page 36)
DIP 2
PROGRAMMING (See Point C)
DIP 2-1 PROGRAMMING OF PEDESTRIAN OPENING (See Point D)
DIP 1-2 SAVE/DELETE RADIO CODES FOR COMPLETE OPENING (DIP 1 ON followed
by DIP 2 ON) (POINT E)
DIP 1-3 SAVE/DELETE RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 ON
followed by DIP 3 ON) (POINT F)
DIP 1-2-3 SAVE/DELETE RADIO CODES FOR RELAY R-AUX COMMAND (point G)
DIP SWITCHES CONTROL
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON-activated).
DIP 8-9-10-11
IS NOT AVAILABLE
DIP 12
Activate the radio system SUN/MOON (ON) - SUN-PRO (OFF)
DIP 13
Contactors management (ON - activated) - NOTE: Even if enabled, DIPs 8-9-10-11
are excluded from their operation
DIP 14-15-16
IS NOT AVAILABLE
TORQUE TRIMMER - Electronic regulator for motor torque
IS NOT AVAILABLE
LOW SPEED TRIMMER - Electronic regulator for low speed on approach
IS NOT AVAILABLE
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN
openings
default NOT ACTIVATED and LED DL11 OFF (trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic
closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11
ON (trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a
maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2
seconds to a maximum of 30 seconds.
Ex: With TCA trimmer setted halfway, you will have 1 minute pause after the total opening
and 15 seconds of pause after the pedestrian opening prior to have the auto-close of
the gate.
R-AUX - AUXILIARY RELAY CONTACT (NO)
By default this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3 minutes
at each command, with time renewed at each command.
You can activate the R-AUX contact by TRANSMITTER by performing the memorization
procedure described in point G.
ELECTRONIC BRAKE
IS NOT AVAILABLE
GRADUAL START
IS NOT AVAILABLE
LED WARNINGS
DL1
PROG programming activated
DL2
Gate opening
DL3
Gate closing
DL4
Opening limit switch LSO
DL5
Closing limit switch LSC
DL6
STOP command (NC)
DL7
PHOTO 1 contact (NC)
DL8
PHOTO 2 contact (NC)
DL9
EDGE 1 contact (NC)
DL10 EDGE 2 contact (NC)
DL11 TCA - automatic closure time enabled
DL12 Remotes programming enabled
DL13 L1 managed by APP
DL14 Encoder enabled
DL15 PROG and RADIO (on MOLEX connector) commands (green)
B.I.O
Clock command (NO)
PED.
Pedestrian command (NO)
START Single impulse command (NO)
CLOSE CLOSE command (NO)
OPEN OPEN command (NO)
PROBE
NOT AVAILABLE
POINT C - TIMES PROGRAMMING
N.B .: During the programming the safety functions Coast, Photocells and Stop button
N.B .: If the STOP, PHOT 1, PHOT 2, EDGE 1 and EDGE 2 inputs are not connected,
N.B .: The start slow-down point is automatically determined in the time programming phase
N.B.: TO REPEAT THE PROGRAMMING REPOSITION THE GATE TO 20 CM FROM THE
1 - N.B .: POSITION THE GATE TO ABOUT 20 CM FROM THE CLOSING LIMIT SWITCH.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG or START or OPEN button or the button of the remote control dedicated
to the total opening (if previously programmed). The gate will start a series of movements.
DO NOT PASS IN FRONT OF THE PHOTOCELLS WHILE THE GATE IS MOVING. The
programming ends when the gate is closed and the DL1 LED is off.
4 - AT THE END OF PROGRAMMING, RESET THE DIP 2 ON OFF.
D - PROGRAMMING OF PEDESTRIAN OPENING TIMES
With closed gate and closing limit switch engaged (mandatory).
1 - First set DIP 2 to ON (LED DL1 flashes quickly) and after DIP1 to ON (LED DL1 flashes
slowly).
2 - Press the PED pedestrian button. or the remote control button dedicated to the pedestrian
opening (if previously programmed) => The gate opens.
3 - Press the pedestrian button PED. to stop the run (thus defining the opening of the gate).
4 - Press the pedestrian button to start closing.
5 - When the closing limit switch is reached, reset DIP1 and 2 to OFF.
During programming, the safety devices are active and their intervention stops the
programming (the LED from blinking remains lit steadily).
To repeat the programming position the DIP1 and 2 on OFF, close the gate and repeat the
procedure described above.
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING
ATTENTION: before storing the radio codes, use DIP 14 to select which transmitters to use:
DIP 14 OFF: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
SUN-PROX 2CH 2-channel - red keys and yellow led cod. ACG6220
SUN-PROX 4CH 4-channel - red keys and yellow led cod. ACG6224
DIP 14 ON (default): You can store transmitters with fixed code SUN and MOON:
SUN 2CH 2-channel - blue keys and white led cod. ACG6052
SUN 4CH 4-channel - blue keys and white led cod. ACG6054
(red)
SUN CLONE 2CH 2-channel - blue keys and yellow led cod. ACG6056
(green)
SUN CLONE 4CH 4-channel - blue keys and yellow led cod. ACG6058
(red)
MOON 2CH 2-channel - black keys and yellow LED cod. ACG6081
(green)
MOON 4CH 4-channel - black keys and yellow LED cod. ACG6082
(red)
ATTENTION: it is not possible to memorize at the same time transmitters with fixed code and
(red)
(red)
Programming can be done only when the gate is stationary.
(red)
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 seconds.
(red)
2 - Press the TRANSMITTER button (usually channel A) within the allotted 10 seconds. If
(red)
the remote is memorized properly LED DL12 blinks green and a buzzer tone confirms
(red)
the correct memorization. The 10 seconds for programming the codes are automatically
(two colors)
renewed, with LED DL12 which flashes red, in order to store the next transmitter.
(blue)
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED DL12
(red)
stops flashing.
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
(green)
5 - End of procedure.
(green)
(green)
(green)
34
are active and their performance level is pl "b" according to EN13849-1. their
intervention stops the programming (the led DL1 from flashing remains lit
steadily).
make jumpers between COM A +/STOP/PHOT 1/PHOT 2/EDGE 1/EDGE 2 before
proceeding with programming. N.B .: In this case the safety Edge, Photocells
and Stop button will be ignored.
and 50 ÷ 60 cm is activated before reaching the opening or closing limit switch.
CLOSING LIMIT SWITCH AND FOLLOW THE PROCEDURES BELOW.
(1000 CODES MAX) - with radio module ACG8069
transmitters with variable code.
(green)