3.5 Direct Test Leads Connection Mode – Tracing an Individual Pipe or Cable
Direct connection with test leads is the most reliable method to trace individual cable or a pipe.
�WARNING
• Only authorized personnel should make connections to cables.
• The Transmitter can be connected ONLY to de-energized wires or pipes.
• Do not touch metal parts of the connection clips when connecting to the line or when the Transmitter is on as
they may exceed 30 V rms.
• For shielded cables, always connect to the sheath of that cable. The sheath will stop the tracing signal if the
Transmitter is connected to one of the internal wires.