Télécharger Imprimer la page

Dometic Buttner MT BCB 30/30/20 IU0U Instructions De Montage Et De Service page 35

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
Charge/ retention current, regulated
for START
"Ntz" signal output, indication
light/max.
Booster operation
Input voltage range START
(EURO 6 +), D+ controlled
Input over-voltage cutoff START
(EURO 6 +)
Max. power consumption on START
Max. current consumption on START
• DIP switch position "max"
• DIP switch position "Limit Boo"
Charge/buffer/load current, regu-
lated for START
Activation-control "D+" input, for D+,
terminal 15, ignition
TR terminal, high load relay/max.
Pulser operation
Double-peak current pulses, short-
time
Under-voltage cutoff
General technical data
Reverse current from battery, stand-by,
no mains
Voltage ripple
Limitation of charging voltage BORD
External over-voltage cutoff BORD
Protection class/ type
Ambient temperature for operation
Ambient humidity
Dimensions (W x D x H)
Weight
Inspection/certification
MT BCB30/30/20
0 A – 4 A
12 V/1 A
10.5 – 16.0 V
>16.5 V
470 W
0.1 – 42 A
0.1 – 32 A
0 A – 30 A
8 – 16 V
12 V/1 A
>100 A
<12 V
0.016 A
< 30 mVrms
15 V
15.2 V
270 x 300 x 70 mm (fig. l, page 13)
3.65 kg
4445103619
MT BCB40/40/30
0 A – 5 A
12 V/1 A
10.5 – 16.0 V
>16.5 V
630 W
0.1 – 57 A
0.1 – 43 A
0.1 A – 40 A
8 – 16 V
12 V/1 A
>100 A
<12 V
0.016 A
< 30 mVrms
15 V
15.2 V
I/IP21
–20 °C to +45 °C
≤ 95 %, non-condensing
3.80 kg
MT BCB60/60/40
0 A – 10 A
12 V/1 A
10.5 – 16.0 V
>16.5 V
930 W
0.1 – 82 A
0.1 – 65 A
0.1 A – 60 A
8 – 16 V
12 V/1 A
>100 A
<12 V
0.016 A
< 30 mVrms
15 V
15.2 V
3.95 kg
35