.1.. WARNINGS

Attention: Before attempting any work on the control unit (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
- Connect the earth cable to the terminal on the J9 connector of the unit (see fig.2).
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical
noise, use separate sheaths or a screened cable (with the screen earthed)

.2.. TECHNICAL.SPECIFICATIONS

0 V~ (+6% -0%) - 50/60 Hz
Power supply
voltage *
5 V~ (+6% -0%) - 50/60 Hz
Absorbed power
Motor max. load
Power supply
for accessories
Accessories max.
current
Operating ambient
temperature
F = F 0A - 50V F = T 0,8A - 50V
Protection
fuses *
F = F 0A - 0V F = T 0,8A - 0V
Programmable (from 0 to 4 minutes)
Work time
Pause time
Programmable (from 0 to 4 minutes)
Motor power
 programming levels for greater
Programming
Coupling for 5-pin Minidec board,
Rapid connector
Programmable
outputs
multifunction display, BUS technology
Features
and INTEGRATED METALLIC MASS
* The power supply voltage and fuses depend on the version
purchased
CONTROL UNIT
or
7 W
000 W
4 Vdc
500 mA
from -0°C to +55°C
or
Programmable on 50 levels
flexibility of use
Decoder, Receiver RP/RP
4 programmable outputs
in 8 different functions
Management of slow-downs,
DETECTOR
624 BLD
.

.3.. LAYOUT.AND.COMPONENTS.OF.624BLD

3.1.DESCRIPTION.OF.COMPONENTS

DL
SIGNALS AND PROGRAMMING DISPLAY
LED
INPUT STATUS CONTROL LEDs
J1
LOW-VOLTAGE TERMINAL BOARD
TERMINAL BOARD FOR CONNECTION OF MOTOR, FLASHING
J2
LAMP AND FAN
J3
OPENING LIMIT-SWITCH CONNECTOR
J4
CONNECTOR FOR DECODER MINIDEC / RP RECEIVER
J5
CLOSING LIMIT-SWITCH CONNECTOR
J6
CONNECTOR FOR ROD BREAKING SENSOR
J8
CONNECTOR FOR MOTOR THRUST CAPACITOR
J9
TERMINAL-BOARD FOR 0 VAC POWER SUPPLY
DS1
LOOP  and LOOP  FREQUENCIES SELECTOR
F1
FUSE FOR MOTORS AND TRANSFORMER PRIMARY WINDING (F 5A)
F2
FUSE FOR LOW VOLTAGE AND ACCESSORIES (T 800mA)
F
PROGRAMMING PUSH-BUTTON "F"
+
PROGRAMMING PUSH-BUTTON "+"
-
PROGRAMMING PUSH-BUTTON "-"
TRANSFORMER
TF1

Fig. 1