TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
180
TCA
output
1
240
ti e
OP. D IST.
0
99
SLOUD
CL. D IST.
0
99
SLOUD
PARTIAL
10
99
OPENING
99
OP. F ORCE
99 
CLS. F ORCE
25
99 
OP SPEED
 25
 99
CL SPEED
ainte-
0
250
nance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Automatic
TCA
Closing Time
STEP-BY-STEP
Step-by-step
movement
OVE NT
Movement on
sw ov
endstop
Pre-alarm
PRE-ALAR
Deadman
HOLD-TO-RUN
36
-HIDE SL SMART BT A150-A300
Default
Personal
Definition
Automatic closing
40
time [s]
Activation time of
10
the timed output [s]
Slow-down distance
10
during opening [%]
Slow-down distance
10
during closing [%]
20
Partial opening [%]
Leaf force during
50
opening [%]
Leaf force during
 50
closing [%]
 99
Opening speed [%}
99
Closing speed [%]
Programming num-
ber of operations
0
for maintenance
threshold
[in hundreds]
Cross
out
Default
setting
used
0
Logic not enabled
0
1
Switches automatic closing on
Inputs configured as Start E, Start I, Ped oper-
0
ate with 4-step logic.
0
Inputs configured as Start E, Start I, Ped oper-
1
ate with 3-step logic. Pulse during closing
reverses movement.
0
Logic not active
1
1
Activates the movement reversing when it stops on the endstop
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
0
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is switched to
Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
2
Input 62 is configured as CLOSE UP.
ENGLISH
Waiting time before automatic closing.
Activation length of timed radio channel output in seconds
Slow-down distance for motor(s) during opening, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-
closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted opening-
closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of PED pedestrian
command.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety requirements
are met with the set value (*). Install anti-crush safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the
force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is
generated.
The parameter is set automatically by the autoset function.
WARNING:
It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices where
necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening. WARNING: Once
the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing. WARNING: Once
the parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Allows you to set a number of operations after which the need for maintenance will be reported
on the AUX output configured as Maintenance or Flashing Light and Maintenance .
WARNING: safety devices are not enabled.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Description
Optional extras
step-by-step mov.
3 STEP
CLOSED
OPENS
DURING CLOSING
OPEN
CLOSES
DURING OPENING
STOP + TCA
AFTER STOP
OPENS
4 STEP
OPENS
STOPS
CLOSES
STOP + TCA
OPENS