MAINTENANCE
The gearmotors in the SPIN series need very little maintenance.
However,to ensure they always work properly the door has to be in
good condition: hence we shall describe briefly what you need to
do to keep your overhead garage door efficient.
Attention: no one, except the person who services the equipment
(who must be a specialised technician), should be able to com-
mand the automatism during servicing. Consequently, it is advis-
able to turn the electricity off at the mains (and disconnect
the battery if present) also to avoid possible electric shocks. If
the electricity has to be on for certain checks, check or disable
all command devices (remote controls, push button panels, etc.)
except for the device being used by the maintenance man.
Routine maintenance
Each of the following operations must be carried out every 6
months
(always 750 work cycles).
Overhead garage door
● Lubricate the hinges, telescopic arms and make sure the coun-
terweights slide easily.
Automation system
● check the safety devices work correctly (pneumatic edge,
torque limiting device, release device, etc.). They must be ef-
fective in case of danger and trip as specified during installa-
tion.
Extraordinary maintenance or breaks
If there are any complex jobs that need to be done on electrome-
chanical parts, it is advisable to remove the relative part so that the
repairs can be carried out in the workshop by the manufacturer or
its authorised technicians.
TYPICAL SYSTEM (fig. 19 - fig. 20)
1 gearmotor with control panel (SPIN12QR / SPINQRF)
2 gearmotor without control panel (SPIN12 / SPINF)
3 control card +container (only for SPIN12 / SPINF)
4 sensitive edge
5 flashing light +aerial
6 key selector
7 photocells
8 switch
SPINF / SPINQRF
230 Vac
a
3x1,5 mm²
b
4x1,5 mm² + 3x0,5 mm²
c
2x0,5 mm² (TX)
d
4x0,5 mm² (RX)
e
2x0,5 mm²
f
2x1 mm² + 1RG58
g
3x0,5 mm²
h
3x0,5 mm²
i
4x1,5 mm²
The distance between the control unit and the motor must not
exceed 10 - 12 m.
SPIN12 / SPIN12QR: use only M-030000CC50 cable or equiva-
lent.
14
SPIN12 / SPIN12QR
12 Vdc
3x1,5 mm²
2x2,5 mm² + 3x0,5 mm²
2x0,5 mm² (TX)
4x0,5 mm² (RX)
2x0,5 mm²
2x1 mm² + 1RG58
3x0,5 mm²
3x0,5 mm²
2x2,5 mm²
Serie SPIN