Operator Specifications
Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Variable Operating Lengths (Operator Weights)
Maximum Gate/Door Weight
Maximum Gate/Door Width (sectional and one-piece)
Travel Speed
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
External Entrapment Protection Device Inputs (non-contact
and/or contact)
7.5"
(19.1 cm)
4.1" (10.3 cm)
INTRODUCTION
Class II, III, & IV
120 Vac, 4 Amps OR 240 Vac, 2 Amps
24 Vdc Transformer Run / Battery Backup
24 Vdc, 500mA max. for ON + SW (switched)
24 Vdc at 60 watts max.
8 foot (2.4 m) gate - 11.75 foot (3.6 m) operator length (130 lbs. [58.9 kg])
10 foot (3.1 m) gate - 13.75 foot (4.2 m) operator length (145 lbs. [65.7 kg])
12 foot (3.7 m) gate - 15.75 foot (4.8 m) operator length (160 lbs. [72.5 kg])
14 foot (4.3 m) gate - 17.75 foot (5.4 m) operator length (175 lbs. [79.4 kg])
16 foot (4.9 m) gate - 19.75 foot (6.0 m) operator length (190 lbs. [86.2 kg])
1000 lbs. (453.6 kg)
22 ft. (6.7 m)
Default - 8 inches (20.3 cm) per second
Fast - 11 inches (27.9 cm) per second (open speed only)
HCT08, HCT10 and HCT12 - Continuous
HCT14 and HCT16 - 500 cycles a day
Continuous
-20°C to 60°C (-4°F to 140°F)
Provided
Main board - up to 2 close entrapment protection devices and 1 open entrapment
protection device.
Expansion board - up to 3 entrapment protection devices configurable to either close or
open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU .
HCT08: 139" (353 cm)
HCT10: 163" (414 cm)
HCT12: 187" (475 cm)
HCT14: 211" (536 cm)
HCT16: 235" (597 cm)
7
23.8"
(60.3 cm)
7.8"
(19.9 cm)
17.5"
(44.5 cm)