Télécharger Imprimer la page

Haverland HT10PCT Manuel D'instructions page 30

Publicité

Les langues disponibles

Les langues disponibles

control
wire(Neutral).
Heater
CAUTION: Before working, turn off the electricity
at the main breaker.
The device must be installed vertically.
- The installation must be carried out in the state
of the art and comply with the standards in force
in the country.
- The unit must be connected in a standard wall
box at 25 cm or more above the ground.
- The appliance must not be connected to a wall
outlet with plug.
- The device must be powered by a dedicated
line and protected by a 30mA RCD 16A
calibrated. No other appliance or outlet must not
be connected to this circuit breaker.
box,
brown
L: Brown
N: Blue or grey
PROG: Black
wire(Phase),
Control box
Program control box
8
blue

Publicité

loading

Ce manuel est également adapté pour:

Ht15pctHt20pctMedusa-10Medusa-15Medusa-20