Adjustment Of Gas Flow; Using Trigger Modes - Magmaweld RS 200 MK Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

22
Operation
A: Suitable wire pressure and conduit dimensions
B: The wire is distorted since the pressure lever is too tight.
C: The roller surface is deteriorated due to excessive pressure on the pressure lever.
EN
D: The conduit length of the roller is small for the wire used. The shape of the wire is distorted.
E: The conduit length of the roller is big for the wire used. The wire cannot be transmitted to the welding area.

3.5 Adjustment of Gas Flow

Make the gas adjustment and gas test by lifting the wire feed roller pressure lever!
• Adjust the gas flow with the flow control valve.
• Practical gas flow rate (CO₂, Ar, mixture) is 10 times
of wire diameter. For example, if the wire diameter
is 0.9 mm, the gas flow rate can be adjusted as
10 x 0.9 = 9 l/min.
• You can use the table on the side for more precise
flow adjustment.
• After adjusting the gas flow, lift the thrust bearing
arm and close the wire feed unit door.

3.6 Using Trigger Modes

• The trigger mode switch selects 2-position, 4-position or pnt position.
• The 2-position operates as shown in Figure 15.
• The 4-position operates as shown in Figure 16. The 4-position provides ease of use for the welder in
long-term and automatic welding operations.
• In the pnt mode, the welding starts at the moment the trigger is pressed, the welding continues until the set
time period is on and stands by as long as the off-time period. The process continues in this manner until the
trigger is released and the welding stops as soon as the trigger is released.
1
Gas starts instantly
Switch is triggered
Current starts instantly
Wire feeding starts
after pre gas
Figure 15 : Using the 2-Position
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Figure 14 : Pressure Setting and Roller Selection Mistakes
2
Wire stops instantly
Gas starts instantly
Switch is released
Switch is triggered
Current stops after
Current starts instantly
burn back
Wire feeding starts
Gas stops after post gas
after pre gas
RS 200 MK - RS 250 MK - RS 300 MK - RS 350 MK - RS 400 MK
Mild Steel
0.8
8 lt/min
and
Flux Cored
7 lt/min
Metal Cored
0.9
9 lt/min
8 lt/min
1.0
10 lt/min
9 lt/min
1.2
12 lt/min
11 lt/min
1.6
16 lt/min
15 lt/min
Note: Recommended values in standard conditions.
1
2
Gas goes on
Gas goes on
Switch is released
Switch is triggered
Current goes on
Current goes on
Wire goes on
Wire goes on
Figure 16 : Using the 4-Position
Stainless
8 lt/min
Aluminium
8 lt/min
Steel
9 lt/min
9 lt/min
10 lt/min
10 lt/min
12 lt/min
12 lt/min
16 lt/min
16 lt/min
3
4
Wire stops instantly
Switch is released
Current stops after
burn back
Gas stops after post gas
www.magmaweld.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rs 250 mkRs 300 mkRs 350 mkRs 400 mk

Table des Matières