Gate-open warning light: ................................................... 24Vac 3W max
Blinker: ............................................................................... 230V 40W max
Dimensions: ............................................................................. see figure 1
Fuses: ...................................................................................... see figure 2
(* other voltages available on request)
4) TERMINAL BOARD CONNECTIONS (Fig.3)
WARNING – During the wiring and installation operations, refer to the
current standards as well as principles of good technical practice.
The cables must be tied by additional fastening next to the terminals, by
means of clips for example.
All the operator wiring operations must be carried out by qualified personnel.
JP1
1
GND terminal
2-3
Single-phase mains supply 230V±10% 50Hz (2=N) (3=L)
JP2
4-5
Blinker connection (mains voltage) 40W Max.
6-7-8-9
Motor connection:
6 operation 1 + capacitor
7 common (blue)
8 operation 2
9 capacitor
JP3
10-11
Output 24V~ 1A max – power supply for photocells or other
devices.
12-13
Gate-open warning light output (N.O. contact)
10-14
24V~ output for supply to photocell transmitters
15-16-17
Connection of safety devices checked (see fig. 7 to 14)
18-19-20
Connection of safety devices checked (see fig. 7 to 14)
JP5
Encoder connection
WARNING! The maximum length of the connection cable of the
encoder should not exceed 3.00 mt.
JP8
21-22
Open-Close button (N.O. Start), key selector.
21-23
Block button (N.C. Stop). If not used, leave jumped.
21-24
Photocell input (N.C.). If not used, leave jumped.
21-25
Opening limit switch connection (N.C. SWO). If not used, leave
jumped.
21-26
Closing limit switch connection (N.C. SWC). If not used, leave
jumped.
21-27
Pedestrian button connection (N.O. Ped)
21-28
Open-Button connection (N.O. Open)
21-29
Close-Button connection (N.O. Close)
21-30
Rubber edge connection (N.C.). If not used, leave jumped.
21-31
Timer input connection (N.O.). If the contact is open the leaves
close and the gate is ready for normal operation. If the contact
is closed (N.C.), the leaves open and remain open until the
contact is opened.
JP9
32
Photocell check input (PHOT FAULT) (see fig. 7 to 14)
33
Electric edge check input (EDGE FAULT) (see fig. 7 to 14)
38-39
Antenna input for radio-receiver (38 signal - 39 braid). Cable
RG58
5) PROGRAMMING
The control panel provided with a microprocessor is supplied with function
parameters preset by the manufacturer, suitable for standard installations.
The predefined parameters can be altered by means of either the
incorporated display programmer or UNIPRO.
In the case where programming is carried out by means of UNIPRO,
carefully read the instructions relating to UNIPRO, and proceed in the
following way.
Connect the UNIPRO programmer to the control unit through the UNIFLAT
accessory (See fig. 5). Enter the "CONTROL UNITS" menu, and the
"PARAMETERS" submenu, then scroll the display screenfuls using the up/
down arrows, and set the numerical values of the parameters listed below.
For the function logics, refer to the "LOGIC" submenu.
In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the "configuration" paragraph.

6) CONFIGURATION

The display programmer is used to set all the LEO-D-MA control panel
functions.
The programmer is provided with three pushbuttons for menu scrolling and
function parameter configurations (Fig. 2):
14 -
LEO-D-MA - Ver. 01
INSTALLATION MANUAL
+
menu scrolling/value increment key
-
menu scrolling/value reduction key
OK
Enter (confirm) key
The simultaneous pressure of the + and – keys is used to exit the active
menu and move to the preceding menu.
If the + and – keys are pressed simultaneously at the main menu level
(parameters, logics, radio, language, autosetting), programming is exited and
the display is switched off (the OK message is displayed).
The modifications made are only set if the OK key is subsequently pressed.
When the OK key is pressed for the first time, the programming mode is
entered.
The following pieces of information appear on the display at first:
-
Display Software version
-
Control unit Software version
-
Number of total manoeuvres carried out (the value is expressed in
thousands, therefore the display constantly shows 0000 during the first
thousand manoeuvres)
-
Number of manoeuvres carried out since the latest maintenance operation
(the value is expressed in thousands, therefore the display constantly
shows 0000 during the first thousand manoeuvres)
-
Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the first
menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus
available.
The predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.
6.1) Parameter Menu (PARAM)
1- Pedestrian opening (Mt. ped) [ 001.0 m ]
Set the numerical value of the pedestrian opening from 10 cm (000.1) to
6m (006.0).
2- Automatic Closing Time (TCA) (tca) [ 40s ]
Set the numerical value of the automatic closing time from 1 to 180 seconds.
3- Encoder (Encoder) [ 2 ]
0: manual operation without encoder: timed slow-down, obstacle
detection function not active. (The encoder can be disconnected).
1: manual operation with encoder used as position sensor to acquire
slow-down values. Obstacle detection function not active.
2: semi-automatic operation: slow-down and obstacle detection by
means of encoder (default).
than that specified in the EN 12453 standard.
4- Opening torque (open torque) [ 50% ]
Set the motor opening torque value between 1% and 99%.
5- Closing torque (cls. torque) [ 50% ]
Set the motor closing torque value between 1% and 99%.
6- Slow-down torque (slov torque) [ 50% ]
(UNIPRO ⇒ Advanced parameters ⇒ address 5)
Set the motor opening and closing slow-down torque value between 1%
and 99%.
7- Brake (Brake) [ 0% ]
Set the required brake value between 0 and 99%, compatibly with the
weight of the gate and the existing stresses.
8- Zone (zone) [ 0 ] (UNIPRO ⇒ Advanced parameters ⇒ address 1)
Set the zone number between a minimum value of 0 and a maximum value
of 127. See paragraph 7 on "Serial connection".
9- Slow-down Distance (Cm. rall) [ 000 ]
(UNIPRO ⇒ Advanced parameters ⇒ address 3)
Set the required slow-down distance for opening and closing between 0
cm and 100 cm The 000 cm value does not carry out any slow-down.
NOTE: If a slow-down distance value other than 000cm is set, after the
first manoeuvre, power failure, reset, or manual gate release, the control
panel carries out a complete manoeuvre at reduced speed, in order to
learn the length of gate stroke.
6.2) Logic Menu (logic. )
- TCA ( tca ) [ ON ]
ON
Activates automatic closing
OFF Excludes automatic closing
3 Steps (3 step) [ OFF ]
-
ON
Enables 3-step logic. A start impulse has the following effects:
WARNING: Check that the impact force value measured at
the points established by the EN 12445 standard is lower
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.