6. MAINTENANCE
CAREFUL!
All adjustments have to be carried out exclusively by killed nd qualified personnel,
who know the electro-pump and the relevant manual very well.
While servicing the electro-pump, it is absolutely necessary to adopt all the
useful measures in order to avoid the accidental start of the group itself
-
The general switch on the power group must be blocked on position
"0" through a padlock.
-
The key to the padlock must be given to a maintenance man who will
hold it for all the duration of the servicing.
Always keep in mind all the main possible risks and the safety instructions as in
chapter 3 "security".
• FULGURATION HAZARD
MAINTENANCE WHILE PARTS ARE IN MOVEMENT IS STRICTLY FORBIDDEN.
IN CASE OF TOXIC/HARMFUL FLUIDS, ALWAYS DECONTAMINATE THE PUMP
BEFORE SERVICING.
AFTER ANY MAINTENANCE SERVICE, IT IS ALWAYS NECESSARY TO BRING
THE MACHINE AND ITS SYSTEM TO THE INITIAL STATUS, COM- PREHENSIVE
OF THE PROTEZIONI AND THE DISASSEMBLED SECURITY DEVICES.
In order to obtain a good maintenance service, it is important to
-
verify immediately the causes of any possible anomaly (excessive noise,
overheating, overflowing fluids)
-
pay particular attention to the security devices
-
use all documentation provided by the builder (usage manual,
schemes for the electrical system, and so on)
only use qualified devices for maintenance as well as original spare parts
6.1 • PERIODICAL OILING
GREASY OILING
Use high quality mineral-base grease with anti-oxidation, anti-corrosion and
anti-foam additives.
As a supplementary information, we list hereafter some recommended type of
grease:
CASTROL....................SPHEEROL
IP ...................................ATHESIA EP
CHEVRON .................... DURALIT
BP ................................ ALVANIA EP
MOBIL .......................... MOBILUX EP
ESSO ........................... BEALON EP
An excessive quantity of grease can cause an overheating of the bearings.
Oil lubrification intervals (actual operation hours).
First change
Folliwing changes
300 hours
3000 hours
Unfavourable working conditions, such as a high room temperature,
a high air humidity, dusty air, an aggressive industrial atmosphere etc., make it necessary
to control the bearings more often; in particular cases, they will need to be washed and re-
greased (with new grease).
Before substituting the grease, completely remove the used one (fig. 36) in order to obtain a
correct substitution, let personnel of technical assistance do this maintenance.
Max. durations
1 year