50/148 Bosch Rexroth AG
7 Transporting system boxes
6.2.2 Interface X4.2
3
6
7
Figure 22: X4.2 Out Connecting socket 8channel
(female) (Front view side of the system
boxes)
Pin Signal
Description/
Function
1
ARC1_A
Serial
control bus +
2
ARC1_B
Serial
control bus –
3
VCC_iso
Supply voltage
4
GNDiso
Reference
potential
external
5
BA- (GNDiso)
6
ARC2_A
Serial data
bus +
7
ARC2_B
Serial data
bus –
8
n.c.
Table 11:
7
Transporting system
boxes
Suitable transport safety devices must be
provided when transporting system boxes,
depending on the transport position.
4
5
2
8
1
Voltage/
Current/
Standard
5 V, RS485
5 V, RS485
5 V, 0,1 A
5 V, RS485
5 V, RS485
SBH.../SB... | 3 609 929 816/2009-02
8
Disposal and
environmental
protection
8.1
Products
Products manufactured by us can be sent
back to us free of charge for disposal. A
prerequisite for this is, however, that they do
not have any films from e.g. oils, grease, or
other contaminants.
No inappropriate foreign matter or
components may be included in the returned
shipment.
Send the products free delivery to the
following address:
Bosch Rexroth Electric Drives and Controls
GmbH
Schraub- und Einpress-Systeme
Fornsbacherstr. 92
71540 Murrhardt, Germany
These instructions are printed on recycled
paper manufactured without chlorine.
8.2
Packaging
The packaging material consists of
cardboard, wood, and styrofoam. They can
be recycled without any problems at every
point of acceptance for such materials. Due
to ecological reasons, returning empty
packing to us should be avoided.