ASSEMBLY & INSTALLATION
Letter references in parenthesis (A) refer to the included Identification Key. Dashed numbers in
parenthesis (Fig. 1-1) refer to specific point of an illustration or image
DUAL VOLTAGE
TYPE
INPUT
115V-20A
ARC
230V
115V-15A
MIG
230V
115V
TIG
230V
X = Duty cycle%age
I2 = Welding Current
U2 = Secondary Voltage with Welding Current I2
INSTALLATION SET UP FOR ARC (STICK) WELDING
Please install the machine strictly according to the following steps.
POWER REQUIREMENTS
The power cord supplied with this welding unit is designed to handle the maximum power
required (see Specifications). Refer to the welding unit's data plate and ensure the power
supply can meet those requirements.
CONNECTING THE POWER LEADS
1.
Connection of Output Cables - An electrode may require either a positive or a negative
charge for optimum results. Connect the electrode holder to the Positive Outlet Socket (I)
or Negative Outlet Socket (G) based on the
electrode manufacturer's information for
the correct polarity set up.
Figure 4 represents the default
configuration for ARC with the ground lead
connected to the positive lead (Fig. 4-1)
and the electrode holder connected to the
negative lead (Fig. 4-2).
2.
Turn the power source on and select the
ARC function with the welding mode knob
(Fig. 4-3).
12
180 MULTI-PROCESS MIG-ARC-TIG WELDER
RATED CURRENT
27.5A
30A
21.4A
30.2A
21.4A
22.6A
OUTPUT
10A/20.4V~100A/24V
10A/20.4V~160A/26.4V
30A/15.5V~100A/19V
30A/15.5V~180A/21.5V
10A/10.4V~100A/14V
10A/10.4V~180A/17.2V
4-1
For technical questions call 1-800-665-8685
DUTY CYCLE
X
I2
25%
100A
60%
65A
100%
50A
25%
160A
60%
103A
100%
80A
25%
100A
60%
65A
100%
50A
25%
180A
60%
116A
100%
90A
25%
110A
60%
65A
100%
50A
25%
180A
60%
116A
100%
90A
4-3
4-2
V1.0
U2
24V
22.6V
22V
26.4V
24.1V
23.6V
19V
17.3V
16.5V
23V
19.8V
18.5V
14V
12.6V
12V
17.2V
14.6V
13.6V
Table 1