Enables or disables door stop before the opening mechanical stop
ON: The control unit stops the door around 5 cm before the mechanical stop.
SASO
In this way stop is progressive and without vibrations.
OFF: The control unit stops the door on the opening mechanical stop
The photocell checks are activated or deactivated. Before the closing operation,
the control unit checks the switching of the photocell contact. If the checks are not
tst1
successful, the door will not close.
On: activated check on photocell
Off: deactivated check on photocell
The "ESA" energy savings function is activated or deactivated.
On: Enabled energy savings. After around 10 sec of non-operation, the power supply
is cut off from the accessory output and the system switches to stand-by.
esa
Off: Disabled energy savings. This is to be used should the accessory power supply
output is to be always activated, e.g. if keypads powered at 24VDC or other devices
that need to be always powered, are used.
Adjustment of inversion speed after the activation of amperometric sensor (INVA:ON).
FAMP
On: High reversion speed
Off: Standard reversion speed (recommended value)
The remote storage of the radio transmitter codes is enabled or disabled (see par.
REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
MENU
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-by-step
function.
PP
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second radio
channel.
2Ch
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the SAIR function (see
SAIR parameter).
Sair
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
CLR
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
RTR
The memory of the receiver is entirely erased. Confirmation for the operation is asked.
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4
digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
This function allows to activate the indication of maintenance required after a certain number of operations, preset by the installer.
To activate and select the number of operations, proceed as follows:
Press the <PG> button, OFF is displayed, indicating that the function is disabled (default).
Select one of the numbers shown (from OFF to 100) by using the <+> and <-> keys . The figures express the value of hundreds of
cycles (e.g.: the number 50 means 5000 operations).
Press OK to activate the function. The PROG message is displayed.
The warning of maintenance required is indicated to the user through the flashing of the courtesy light LEDs during the opening and
closing phases.
16
RADIO (RAD)
NUMBER OF CYCLES (Nman)
MAINTENANCE (maci)
FUNCTION