Télécharger Imprimer la page

Beninca CP.JT Mode D'emploi page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
TECHNICAL DATA
Contol unit power supply
Power supply
Output
Motor maximum power
Accessories power supply
Protection level
Operating temp.
Radio receiver
Memory capacity
Wire connections shown in Fig. 1 are described hereunder:
Terminals
Function
L/N
Power supply
Primary
L1/N1
Transformer
Secondary
0V/MOT/AUX
Transformer
M1
Motor
SAFETY
BAR/BAR
EDGE
CLOSE
CLOSE
OPEN
OPEN
PHOT
Photocell
STOP
STOP
P.P.
Step by step
+COM
COMMON
SHIELD/ANT
Antenna
+ 24V -
24 Vac/Vdc
BLINK
Flashing
AUX1
AUX1
RUN SELF-LEARNING AND ANTI-CRUSHING DEVICE SETTING
When operator assembly and wiring is completed, parameters and logic are programmed, self learning allows the operator to learn the
stroke and self adjusts amperometric sensor thresholds.
First of all place the opening and closing mechanical stops:
-
manually release the door and completely close it. Place the closing mechanical stop in the closed position on the driving carrier and
fix it.
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1 motor 24Vdc
220 W
24Vdc 500mA max.
IP40
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64 rolling-code transmitters
CONTROL PANEL CP.JT
WIRE DIAGRAM
Description
Input, 230VAC 50/60 Hz (L-Phase/N-Neutral)
Connector for the connection of the primary transformer
L1: Line
N1: Neutral
Connector for the connection of the secondary transformer
0V: Input, 0V – MOT: 30 VAC - AUX: 18 VAC
Fast connector for the connection of the motor equipped with Encoder
Input, safety edge. A 8.2 Kohm resistance is pre-installed on the terminals.
Safety edge of the resistive type, 8K2: connect the edge to the terminals by eliminating the
pre-installed resistance, as shown in Figure 3.
Safety edge of the mechanical type: connect the edge in series to the resistance, as shown in
Figure 3. When the safety edge is activated, the door movement is stopped and reversed for
around 3sec.
Input, CLOSE push-button (Normally Open contact).
Input, OPEN push-button (Normally Open contact).
A timer/clock can be connected for openings according to timeframes.
Input, photocell is activated in the closing phase (N.C. contact).
STOP button input (N.C. contact).
STEP BY STEP input ( N.O. contact)
Common for all control inputs.
Connection antenna to the built-in receiver
SHIELD: Screen / ANT: Signal
Accessories power supply 24Vdc 500mA max.
Connection to flashing light 24Vdc 15W max.
Normally open (N.O.), clean contact, which is configurable like SCA (open gate indicator
light) through parameter AUX1, second radio channel, courtesy or area light (see Parameter
AUX 1).
13

Publicité

loading