AUTOMATIC PEDESTRIAN CLOSING
Pause times before the automatic pedestrian closing are set with the programming
procedure.
The max. pause time Is 5 minutes.
You can start and stop the pause time using DIP9 (ON started).
SAFETY EDGE IN OPENING(11-12)
If the safety edge intervenes during the opening of the gate, it commands the reversal of
the movement. This reversal will continue even if the safety edge remains pressed.
During closing the safety edge is not active.
When the safety edge is not in used contacts 11-12 must be bridged.
PHOTOCELL 2 (9-12)
If it detects an object during the opening cycle, it then operates the closing of the gate at
the end of the interposition. If it detects one during the closing cycle, it then operates the
opening at the end of the interposition.
This function is particularly helpful when you want the gate to close immediately after you
passed it. If it is not used, jumper the terminals 9-12.
COURTESY LIGHT (7-8)
It is possible to supply 12Vdc power to the coil of a relay, so as to feed one lamp or more
for a minimum period of 1 second and for a maximum period of 4 minutes (controlled by
the TR trimmer fitted on the EXPANDER card).
The relay is activated at every opening or closing.
TRAFFIC LIGHT CONTROL
When the gate is closed, the traffic light is turned off.
The red light (3-4) turns on when the gate opens.
The green light (5-6) turns on when the gate Is open and the red light turns off.
The green light remains turned on until the automatic closing starts.
When the gate closes, the green light turns off and the red light turns on.
When the closing is terminated, the traffic light turns off.
BATTERY CHARGE CARD
Code ACG4646 for K400
The 12Vdc 7 Ah battery recharge time (optional code ACG9510), at the first installation
is 24 hours, with 0,03 current supplied.
WARNING LIGHT FOR THE BATTERY STATE
In case of network voltage drop, with safety battery activation, this warning light turns on,
signalling the power mains failure, and starts blinking only when the battery is charged.
When the warning light blinks, all functions of the control board are inhibited.
The warning light turns off only when the network is supplied with the due voltage and all
commands are ready to work again (the battery recharges only when the network
voltage is available).
NB: If you use too many warning lights, you risk to compromise the logic of the
control unit, possibly causing an operation block.
OPERATION WITH BLACK OUT
If a battery Is connected to the control board, the warning light indicating the battery
state turns on when the voltage is not enough, and signals that the system is operating
with the battery.
Gate operation is guaranteed up to a charge level of about 10V. Beyond this level, the
charge card gives a signal to the microprocessor that stops the gate, making blink the
warning light - gate open - and the warning light - battery state -. Once the network
voltage is available again, the recharge card starts recharging the battery.
You just need to press the remote control (the opening button or the jogging operation
button) to open the gate.
When the gate Is open, operate a closing command or wait until the pause time elapses
and the gate automatically closes. The gate starts from the closing position. When It Is
closed, every normal function Is ready to be activated again.
If no battery is connected to the control board, you do not need to follow any particular
procedure. When the network voltage Is available again, just press the remote control,
the opening button or the button for the jogging operation, in order to open the gate.
When the gate Is open, operate a closing command or wait until the pause time elapses
and the gate automatically closes. The gate starts from the closing position.
When the gate is closed, every normal function is ready to be activated again.
Safety devices are ready to operate during the alignment phase.
RADIO TRANSMITTER MOON
ACG6082 - 433
ACG7026 - 91
CODE LEARNIG SYSTEM RADIORECEIVERS
RX91/A
quarzata and coupling
RX91/A
quarzata and terminal board
RX433/A
super eterodyne and coupling
RX433/A
super eterodyne and terminal board
RX433/A 2CH super eterodyne, 2 channel and coupling
RX433/A 2CH super eterodyne, 2 channel and terminal board
SPARK ANTENNA
In order to make the systems mentioned above give the best performances, you need to
install an antenna tuned on the frequency of the radio receiver installed.
N.B. Pay attention not to let the central wire of the cable to came Into contact with
the external copper sheath, since this would prevent the antenna from working.
Install the antenna vertically and in such a way the remote control can reach it.
SPARK ANTENNA 91 code ACG5454
SPARK ANTENNA 433 code ACG5252.
SPARK BLINKER 12V WITH IN-BUILT INTERMITTENT CARD
NYLON OLIVE
code ACG4010
Pag. 23 di 36
E
N
G
L
ACG6081 - 433
I
ACG7025 - 91
S
H
code ACG5005
code ACG5004
code ACG5055
code ACG5056
code ACG5051
code ACG5052
code ACG7057

Publicité

loading

Ce manuel est également adapté pour:

K400 plus 12vKit k400 plus scKit k400 plus cc