N
- Temperature range
G
- Moisture
L
- Power supply voltage
- Transformer power supply
I
- Frequency
S
- Max. power consumption of the card, loadless 120 mA
- Transient mains power drops
H
- Max. capacity of the warning light - gate open 3 W (corresponding to 1 3W lamp or to
- Max. load at the blinker output
- Available current for photocells and accessories 1A 12Vdc
- Available current on the radio connector
- Battery power supply
- Transformer capacity
- All the inputs must be used as clear contacts because the power supply is generated
inside (safe power) the control panel, and it has been laid down in such a way to
guarantee a double or strengthened insulation in relation to the parts with dangerous
power.
- Eventual external circuits connected to the outputs of the control board or of the
expander card must be carried out making sure that a double or strengthened insulation
is used in relation to parts with dangerous power.
- All inputs are run by a programmed integrated circuit which does a self check every
time it starts operating.
TECHNICAL DATA
0 ± 55°C
< 95% without capacitor
230V~ or 120V~ ±10%
12Vac
50/60 HZ
100mS
5 LEDS with 2,2 kΩ resistance In
series)
10W 12Vdc
200mA 12Vdc
10,2÷13Vdc
180VA
OPTIONALS
For the connections and the technical data of the fixtures follow the
relevant handbooks.
EXPANDER 1 2 V
EXTRA FUNCTIONS
!! FEED THE EXPANDER 12V CARD IN WHEN POWER IS NOT SUPPLIED !!
ATTENTION: Before connecting the connector 11, intended for safety edge during
opening, make sure that the version of the software of the command card is:
- v.02 or later versions => for command card KS 12v.
software version
In case the version of the software is earlier than the one indicated do not use the
connector 11, LEAVE IT FREE.
CAPTION
TR
=> Adjustment trimmer for the courtesy light time
1-2 => 12Vdc power supply for photocells, FOTOCOSTA units, etc....
3-4 =>
Traffic light 1 contact
5-6 =>
Traffic light 2 contact
7-8 =>
Courtesy light contact
9
=> Photocell 2 (NC) contact
10
=> Pedestrian opening command (NO)
11
=> Contact for safety edge when gate opens (NC) (ATTENTION - see previous
note)
12
=> Common unit
EXPANDER 1 2 V
D2
Photocell 2 contact signal
D3
Signal for pedestrian opening contact
D4
Signal for safety edge
D5
Voltage presence
N.B.: LED D2, LED D4 and LED D5 must always be turned on for a correct
functioning.
PEDESTRIAN OPENING BUTTON (10-12)
This command operates the partial opening of the gate and its closing. When the gate Is
partly open, It Is not possible to operate Its total opening using the pedestrian command.
It is possible to close the gate again to open it totally.
Through DIP 5 it is possible to choose the mode of function of the pedestrian command.
If DIP5 is set on OFF position => It is a cyclic command. Every command operates a
change; e.g. open-stop-close-stop-open etc;
Se DIP5 su ON => Commands the opening when gate is closed. If another command is
sent during the opening of the gate it will have no effects. Commands
the closing when the gate id opened. If another command is sent
during the closing of the gate it will re-open the gate.
LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING
1 - First, position DIP2 on mode ON (the LED DL5 blinks quickly) and then DIP1 on
mode ON (the LED DL5 blinks slowly).
2 - Push the pedestrian button => The sliding gate opens.
3 - Push the pedestrian button to stop the gate travel, thereby determining its opening.
4 - Wait as long as you want the gate to remain open (excluded by DIP9 on OFF), than
push the pedestrian button to operate the closing cycle.
5 - When the closing limit switches are reached, position DIP1 and 2 back on mode OFF.
Safety devices are ready to operate during the programming and their action stops it (the
LED does not blink anymore but remains turned on).
To repeat the programming, position DIP1 and 2 on mode OFF, close the gate and
repeat the procedure described above.
CARD (ACG5471)
CARD LED SIGNALS
D5
D4
D3
D2