Télécharger Imprimer la page

RIB K400 Instructions Pour L'utilisation Et L'installation page 20

Masquer les pouces Voir aussi pour K400:

Publicité

Les langues disponibles

Les langues disponibles

Pag. 20 di 36
E
N
G
L
I
S
H
Wiring and fixing of power
supply cable
ELECTRONIC BOARD KS 12V
J1 => EXP.12V
Connector for EXPANDER card 12V (ACG5471)
J2 => SEC.TRANSF.
Connector for the second transmitter
J3 => BATTERYCHARGER Connector for battery charge card
J5 =>
DO NOT TOUCH THE JUMPER !
IF IT IS REMOVED THE OPERATOR DOESN'T MOVE !
J6 => SEC.LOCK
Connector for the manual device safety release
J7 => ENCODER
Connector for the Encoder
J9 => Connector for limit switch connection
LSO
Limit switch contact, stopping the motor opening
COM.
Contacts common unit
LSC
Limit switch connector, stopping the motor closing
ELECTRIC CONNECTIONS
A - CONNECTIONS
Code BC07051
J12
AERIAL
Radio antenna
COM
Contacts common unit
PHOT.1 NC Photocells contact (NC)
J13 => MOTOR
Motor power supply
J14
STOP
Stop button contact (NC)
OPEN
Opening button contact (NA)
CLOSE
Closing button contact (NA)
K BUTT.
Single impulse contact (NA)
D+D-
12Vdc Accessories power supply
SIGNAL
Gate open - signal 3W max.
Buzzer - Wiring acoustic warning (12Vdc max 200 mA)
Blinker (max. 10W 12Vdc) - Cod. ACG7057
SIGN
Warning LED - Battery discharged
J15 => RADIO
Connector for radio receiver
LOW SPEED =>
Adjustment trimmer for the low speed.

Publicité

loading

Ce manuel est également adapté pour:

K400 plus 12vKit k400 plus scKit k400 plus cc