06. Proper and improper use
Proper use
The oil heating unit IDE has been developed for the
generation of hot air and may only be used indoors.
The device can be used for heating large rooms such
as storerooms, workshops, building sites, greenhous-
es and cowsheds. It has been designed for stationary
operation without frequently changing locations.
Any application deviating from the above mentioned
use is deemed inadmissible!
Improper use
The device may not be installed or operated in poten-
tially inflammable and explosive rooms or areas.
The device may not be used in rooms with an insuffi-
cient supply of combustion air.
07. Installation conditions
When choosing the installation location of the oil
heating unit, a number of spatial and technical con-
ditions must be taken into account. Any non-compli-
ance may impair the functioning of the device and/or
of the accessories or result in hazardous situations for
people and property.
The following points are to be observed during instal-
lation:
• The device may only be used indoors.
• The device must be installed in a stable position
and placed on a fireproof surface.
• The device must be installed near a chimney or
external wall.
• The device must be connected to a properly se-
cured mains socket.
• The installation room of the device must be suffi-
ciently ventilated.
• The minimum distance of the intake opening of the
device to the wall must be at least 2 m (see figure).
• The minimum distance of the device to inflamma-
ble materials must be at least 3 m.
• The intake and exhaust openings must not be covered.
B - 4
• There may be no walls or large objects near the
device.
• A sufficient number of fire-extinguishing systems
must be available.
08. Description of device
The oil heating unit IDE 30, IDE 50 and IDE 60 consists
of the following components:
Oil heating unit
A air outlet
B housing cover
C handle
D lower cover
E temperature controller
F wheel
G temperature display
H main switch
Operating Manual – IDE 20 D/ 30 D / 50 D / 70 D
min. 2 m
I frame
J fuel tank cap
K pressure gauge
L air inlet (motor)
M heating oil filter
N fuel gauge
O tank
EN