21 comando attivazione monitor
esterno
Funzioni dei morsetti della
presa VPM/241U del modulo
di chiamata PA/212 (fig. 4)
1÷12
chiamate 1÷12
13
comune chiamata (*)
14÷24 non utilizzati
(*) Questo collegamento é utilizza-
to solo in impianti di tipo residen-
ziale.
INSTRUCTIONS
GB
FOR USE
PORTER'S SWITCHBOARD
The unit is made up of a base
module PA/200 which includes the
receiver, control keypad, the
management electronics, one or
more PA/212 call modules, with
memory, for 12 users each, and an
optional PAM/200 monitor module.
The base module and call module
come with a multicore cable
1.70m long with plug attached for
fast coupling with the relevant
sockets.
Base module PA/200
This features the following controls
and indicators, figure 1:
1
Red line engaged LED
2
Green LED, when lit indi-
cates a call from the
entry panel.
3
Yellow LED available for
use with auxiliary servi-
ces.
4
Cradle switch actuator.
5
Volume control for calls
to switchboard.
ON/OFF ON/OFF
switch
luminous green switch-
board ON indicator.
INTERCEPT mode but-
ton with luminous yellow
indicator which lights
when the intercept mode
is enabled (if this func-
tion is enabled, all the
calls from the entry
panels are routed to the
switchboard).
Call transfer button for
transferring calls to the
extensions.
Entry panel enabling
button (only enabled in
intercept mode).
Auxiliary button (stairs
light control, entry panel
selector, etc.; only ena-
bled if the switchboard is
communicating with the
entry panel).
Door lock release button
(only enabled if the swit-
chboard is communica-
ting
with
panel).
Call module PA/212
This features the following controls
and indicators, figure 1:
6
Red
communication
request indicator.
7
Call button for call to
extension.
8
Name card.
Monitor module PAM/200
This features the following con-
trols, figure 1:
9
Contrast control.
10
Brightness control.
Function of the jumper SW1
In residential audio installations
with block entry panel calls to the
porter switchboard via selectors
SI/200, the jumper must be set to
ON, figure 2.
INSTRUCTIONS FOR USING
THE UNIT
Switch the unit on using the
ON/OFF switch, figure 1. After
approx. 1 second, the unit is ready
to work in one of the two operating
modes referred to as DIRECT
mode (NIGHTTIME) and INTER-
CEPT mode (DAYTIME).
DIRECT mode (NIGHTTIME)
Callers can call and converse
directly with the tenants from the
entry panel.
If the entry panel also features the
porter call button, where neces-
sary the caller can also call the
porter (the tenant is out, requests
for information, etc.).
The porter is advised of a call from
the entry panel by an audible
signal and by the luminous green
with
indicator 2 lighting (and the moni-
tor coming on, where fitted).
When the receiver is lifted, the
entry panel is put through to the
switchboard; replacing the recei-
ver on the cradle breaks off the
conversation and DIRECT mode
operation is resumed.
If, following the conversation with
the entry panel, the porter finds he
must call the tenant, the call can
be made immediately without han-
ging up. Once the conversation
with the tenant is finished, the
entry panel is put back through to
the porter by simply pressing the
switchboard's cradle switch actua-
tor 4, figure 1.
INTERCEPT mode (DAYTIME)
Press the INTERCEPT button
figure 1.
In this operating mode, any button
on the entry panel, when pressed
by the caller, causes the call to be
made to the switchboard.
The porter is advised of each call
from the entry panel to the switch-
board by the luminous green indi-
cator 2 lighting (and the monitor
the
entry
coming on, where fitted).
Lifting the receiver puts the entry
panel through to the switchboard.
If one of the extension (tenant) call
buttons is then pressed, the swit-
chboard puts the entry panel on
hold (and the caller is therefore
unable to listen to the conversa-
tion with the extension), and the
switchboard is put through to the
tenant called (the picture of the
caller comes up on his monitor)
who has, in turn, lifted his receiver.
When the conversation with the
tenant is finished, the porter can
resume conversation with the
entry panel by simply pressing the
switchboard's cradle switch actua-
tor 4, figure 1, or can put the caller
at the entry panel through to the
tenant by pressing the transfer
button
(the luminous red indicator 1
lights) and replacing his own
receiver.
The conversation between tenants
and callers keeps the line enga-
ged until the set time has elapsed
(approx. 30÷90 secs.), after which
the switchboard resumes its regu-
lar operation and the luminous red
indicator 1 goes off.
If the entry panel calls the switch-
board whilst the latter is communi-
cating with a tenant (the lighting of
the luminous green indicator 2 illu-
strated in figure 1 and an attenua-
ted call note advise the porter of
the call) does not interrupt the
conversation in progress, which
can only be broken off by the por-
ter who, by pressing the cradle
switch actuator 4, figure 1, puts
himself through to the entry panel.
Calling the extensions
In order to call an extension from
the switchboard, lift the receiver
and press the desired call button.
The call note when the switch-
board is calling the extensions is
different to that advising of a call
from the entry panel (second note
generated by the power supplier
VA/200).
The volume of incoming call
signals to the switchboard can be
controlled by means of potentio-
meter 5, figure 1.
If a surveillance camera is instal-
led in the porter's lodge, the tenant
called by the porter will see the
relevant picture on his monitor.
The tenant can also call the porter:
this generates a call note and cau-
ses the luminous red indicator
relating to the extension making
the call to light.
In order to answer a call from an
extension via the switchboard, lift
the receiver and press the corre-
sponding call button; the red indi-
cator goes off.
,
In the case of residential installa-
tions, if the call is addressed to a
tenant in an engaged block, the
call causes the luminous red indi-
cator 1, figure 1, to light for a
moment, and the luminous red
indicator of the tenant remains lit
until the call is attended to.
All the calls from the extensions
are stored by the switchboard and
indicated by the lighting of the
relevant red indicators 6, figure 1.
TECHNICAL FEATURES
Base module PA/200
• Supply voltage: 16÷17.5 VDC,
protected with fuse F1 (fig. 2)
type T 630 mA (fuse: F = fast-
blow; T = delayed).
• Current demand: 100 mA.
• Call note volume control.
• Working temperature range:
from 0 °C to +35 °C.
• Dimensions: 80x230x80 mm.
Call module PA/212
• Current demand: 30 mA (with 6
luminous indicators lit).
• Working temperature range:
from 0 °C to +35 °C.
illustrated in figure 1
• Dimensions: 80x230x55 mm.
Monitor module PAM/200
• CCIR standard (EIA).
• 4" picture tube (10 cm).
• Current demand: 350 mA.
• Horizontal resolution: 450 lines.
• Horizontal frequency: 15,625 Hz
(15,750 Hz EIA).
• Vertical frequency: 50 Hz (60 Hz
EIA).
• Video input: 1 Vpp composite to
75Ω.
• Working temperature range:
from 0 °C to +35 °C.
• Dimensions: 115x230x55 mm.
Function of each terminal
of socket VPM/240 U
of base module PA/200, figure 3
3
video signal
4
video signal shield
− supply voltage
5
6
+
7
call to porter's switchboard
8
audio to porter's switchboard
9
audio from porter's switch-
board
10 entrance engaged signal
11 common call from porter's
switchboard
12 INTERCEPT mode
13 interception 1
14 call from porter's switchboard
relay control
15 common call entry panel
16 common call 1
17 audio enabling control
18 output for call repeater
19 porter's switchboard ON indi-
cator
20 luminous yellow auxiliary indi-
cator (active towards power
supply's negative)
21 entry panel monitor on/off con-
trol
Function of each terminal
of socket VPM/241 U
of call module PA/212, figure 4
1÷12
13
14÷24 not used.
(*) This connection is only used in
residential-type installations.
calls 1÷12
common call (*)
3