Finestra™ Walk-In Bath
Electrical Connections - Pure Air
Risk of electric shock. Connect only to a circuit
protected by a GFCI.
When using electrical products, basic precautions
should always be followed:
•
Always follow local building and electrical codes.
•
Grounding is required. The unit should be
installed and grounded by a qualified electrician.
Two separate GFCI protected circuits are required. Install
a duplex outlet to the wall stud underneath the bathtub, at
least 4˝ (101mm) above the floor. The duplex outlet is not
supplied.
A separate, 120VAC, 15 Amp GFCI circuit is required for
chromatherapy lighting.
A separate, 120VAC, 15 Amp GFCI circuit is required for
the blower.
Reference Illustrations - PureAir™ Bath
J4 Control Panel Schematic Diagram
120VAC
15A
GFCI
Water Level
Sensor Cable
J5 Control Panel Schematic Diagram
120VAC
15A
GFCI
Water Level
Sensor Cable
Installation and Operation
AUX
Control Panel
Blower
Control Panel
DO NOT USE
Control Box
AUX
Blower
Chromatherapy
Lights
www.jacuzzi.com
Reset
Test
Light Control Box
120VAC
Panel
LED Lights
Inside
Inside
Ambient
Temp
RS232
Light 1
Light 4
Light 1
Sensor
240VAC
Inside
Inside
Ambient
LOGO
Panel Blower
Light 2
Light 3
Light 2
Light
120VAC
15A
GFCI
Chromatherapy
Lights
DO NOT USE
Pump
120VAC
15A
GFCI
Page 11