WARNINGS
• All measurements are in centimetres
• The drawings given are not to scale
Info
Mynima shower enclosures are equipped with an integrated
shower tray unit, which is in direct contact with the floor and the
drainage column inserted in the floor.
Corner installation is possible (mod. 140: also in centre
of wall) on finished and covered walls that do not have
skirting and/or protuberances.
IMPORTANT: check that the goods are intact on arrival,
so that any claim made to the forwarding agent will be
prompt.
Provision for drainage
and water supply connections
We recommend that you position the shower enclosure drain as
shown, in position 1 or 1a.
To connect to the hot-cold water supply system (position 5), ac-
cording to the model chosen, we recommend that you use 90°
elbows - 1/2" or pipes (copper) with Ø min. 14mm; the latter
must end with a 1/2" male attachment.
Please use the measurements given.
We also recommend that you do not use connections on supply
pipes, in order to avoid leaks and consequential reduction in wa-
ter jet power.
For correct water jet operation, the pressures and capacities of
the water supply system to the shower enclosure must be en-
sured, as shown in the "Plumbing Requirements" table.
Provision for electrical connection
For all models equipped with electronic functions, a standard ca-
ble must be used for connections to the electrical mains and the
earth system, and prepared as shown in position 2.
If you wish to connect the shower enclosure to an alarm circuit,
a bipolar cable must be used (position 2).
In any case, see the "Electrical Safety" chapter to choose the ca-
bles and installation procedures.
Electrical safety
Jacuzzi
®
MYNIMA TT shower enclosures are safe appliances,
manufactured in compliance with CEI EN 60335-1, CEI EN
60335-2-105; EN 61000; EN 55014 norms and approved by
the SIQ Certification Institute. They are tested during pro-
duction to guarantee user safety. Installation must be carried
out by qualified and authorized personnel, in compliance with the
national provisions in force.
It is the responsibility of the installer to choose the
materials with regard to their use, to carry out the
work correctly, to check the condition of the system
to which the appliance is to be connected and its
suitability in order to guarantee user safety.
Flexa Twin shower enclosures are Class "I" appliances, and must
be anchored securely and connected permanently, without any
intermediate joints, to the electric network and earth system.
The electric network and earth system of the build-
ing must be in working order and must comply with
the provisions of the law and specific regulations in
force in that country.
For connection to the electric mains, it is necessary to install a
disconnecting multiple-pole switch, and place it in an area that
complies with the safety prescriptions for bathrooms. This stan-
dard multiple-pole switch must guarantee a contact opening of
at least 3mm and be suitable for voltages of 220-240V and cur-
rents up to 16A.
The switch and other electrical devices must be lo-
cated, in accordance with regulations, in an area that
cannot be reached by the person using the appliance.
The installation of electrical devices and appliances (sockets,
switches, etc.) in bathrooms must comply with the legal re-
quirements and standards of the country concerned. In particu-
lar, no electrical installation is permitted within 60 cm of the
shower enclosure or at a height of less than 225 cm.
0,6 m
Connection to the electrical system of the building must be made us-
ing a sheathed cable that is not less than H 05 VV-F 3x2,5 mm
The electric system of the building must be e-
quipped with a 0.03 A differential switch.
Jacuzzi
®
MYNIMA shower enclosures are equipped with a con-
nection terminal, positioned next to the crossbar/fixture panel
connection, marked with the symbol
nection of surrounding metal parts, as required by CEI EN
60335-2-105 norms; we recommend that the relevant connec-
tion cable comes out in position 2.
9
0,6 m
2
.
, for equipotential con-