SET-UP INSTRUCTIONS
Set-Up
1. Remove the protective film from the display window on the display head.
2. Ensure the scale base is on a stable, flat surface and that the sides of the base are clear of any obstacles.
3. Utilizing the leveling bubble located at the top of the scale platform, level the scale by adjusting the leveling feet
at each corner of the underside of the base.
Powering the Scale
For AC operation – plug the adapter into the base of the scale and into the power source, or use the DC IN plug
1.
on the back of the display module.
Note: The Auto Off function is only active when the scale is being used with batteries.
2.
For battery operation, see Battery Installation below.
Battery Installation
1. Place the scale on its side. The battery holder is located in the center of the bottom
of the base.
2. Slide the battery cover in the direction of the "open" arrow.
3. Place 6 C-cell batteries into the battery holder. Note the orientation that is shown and
ensure the batteries are placed in the proper direction. Health o meter
recommends using Alkaline batteries. Do not use zinc-carbon batteries.
4. Replace the battery cover.
Note: When powering the scale via batteries, the AC adapter must be completely
disconnected from the scale.
Warning: If the scale will not be used for some time, remove all batteries to avoid a safety hazard. Disposal of
batteries should be done according to the national, regional or local regulations which apply to you for disposal of
batteries.
Locking the Weight Measuring Unit in KG (Applies to KL models only)
Caution: Please make sure you carefully and precisely follow the directions below as you will be in the
PROGRAM MODE of your scale. Any modification outside of what is listed below may greatly affect the
functionality of your scale.
1. Press the ON/OFF button to power on the scale. As soon as you turn on the scale, press the ZERO button once,
the KG/LB button twice, and then the ZERO button once again. The scale will display "CAL".
2. Press the
once and "PROG" will show on the display.
3. Press the ENTER button and OP1-0 or OP1-1 will be displayed.
once and the display will read "OP2-0"for the KG lock function, then press the KG/LB button to
4. Press the
enable KG lock. Your display should read "OP2-1".
until display reads "DONE"
5. Press the
6. Press the ENTER button, the scale will read "START", then read "0.0 Kg"
You have successfully locked your scale into KG Only.
Deactivating KG Lock (Applies to KL models only)
1. Press the ON/OFF button to power on the scale. As soon as you turn on the scale, press the ZERO button once,
the KG/LB button twice, and then the ZERO button once again. The scale will display "CAL".
2. Press the
once and "PROG" will show on the display.
3. Press the ENTER button and OP1-0 or OP1-1 will be displayed.
once and the display will read "OP2-1"for the KG lock function, then press the KG/LB button to
4. Press the
disable KG lock. Your display should read "OP2-0".
until display reads "DONE"
5. Press the
6. Press the ENTER button, the scale will read "START", then read "0.0"
You have successfully deactivated the KG lock on your scale.
P/N UM597KL_KG 599KL_KG 752KL_KG REV20190416_Web
®
Professional
13
Battery compartment