Burner Adjustment Table; Burner Start-Up Cycle - Riello F5 Instructions Pour Installation, Utilisation Et Entretien

Masquer les pouces Voir aussi pour F5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BURNER ADJUSTMENT TABLE

NON-RETROFIT APPLICATIONS
If this burner is being installed in a packaged unit (i.e. Burner comes with a boiler or furnace), follow the instal-
lation and set-up instructions supplied with the heating appliance, as settings will differ from those shown in
this manual.
Actual Firing
Rate 5% ±
US GPH
0.50
0.60
0.75
0.80
0.95
0.75
0.85
1.00
1.10
1.25
1.50
1.65
NOTE:
The above set up charts are a starting point only.
The burner and appliance must be properly set up using proper combustion testing equipment.
Any approved oil burner nozzle type, angle and manufacturer maybe used, as long as input is corresponding
the correct BTU/hr. or US gph input rating of the appliance.
COMBUSTION CHAMBER
Follow the instructions furnished by the boiler/furnace manufacturer. Size retrofit application according to the appropri-
ate installation codes (e.g. CSA B139 or NFPA #31).

BURNER START-UP CYCLE

Normal
Thermostat
Motor
Ignition transformer
Valve
Flame
Lock-out lamp
2903223
MODEL F3 BURNER
Nozzle
Size
GPH
.40 x 60º/80º
.50 x 60º/80º
.60 x 60º/80º
.65 x 60º/80º
.75 x 60º/80º
MODEL F5 BURNER
.60 x 60/ 80º
.65 x 60/ 80º
.85 x 60/ 80º
1.00 X 60/ 80°
1.10 x 60/ 80º
1.25 x 60/ 80º
1.35 X 60/ 80°
~ 12s
Pump
Pressure
PSI
bar
160
11.0
150
10.4
150
10.4
150
10.4
160
11.0
145
10
145
10
145
10
145
10
145
10
145
10
145
10
Lock-out, due to light-failure
~ 12s
13
Turbulator
Air Damper
Setting
Setting
0.0
0.5
1.5
2.0
3.0
0.0
0.5
1.0
2.0
2.5
3.0
4.0
~ 5s
GB
2.3
2.7
3.4
3.6
4.3
2.25
2.5
2.75
3.0
3.5
4.25
6.0
D5229

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

F337261223726222

Table des Matières