Hilti DX 5 Mode D'emploi Original page 15

Masquer les pouces Voir aussi pour DX 5:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
5.9 Switching Bluetooth on and off
▶ Press and hold the pushbutton for 1-2 seconds to switch on Bluetooth.
Note
Bluetooth switches itself off automatically after 2 minutes.
5.10 Resetting the cleaning indicator
▶ Press and hold the pushbutton for 10-12 seconds to reset the cleaning indicator.
Note
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
5.11 Procedure if a cartridge fails to fire
1. Keep the nose of the tool pressed at right angles against the working surface for 30 seconds.
2. If the cartridge still fails to fire, lift the tool away from the working surface. Take care to avoid pointing it
at yourself or other persons.
3. Pull the cartridge strip by hand to advance it to the next cartridge and use up the remaining cartridges
on the strip.
5.12 Tool misfires (cartridge doesn't fire)
WARNING
Heat The tool can get hot through use.
▶ Wear protective gloves.
▶ Allow the tool to cool down.
1. Stop using the tool immediately.
2. Unload and dismantle the tool.
3. Check that you are using the correct combination of magazine, piston and fasteners.
4. Check the buffer, piston and magazine for wear, and replace the parts if necessary.
5. Clean the tool.
◁ If the problem persists after taking the measures described above, further use of the tool is not
permissible.
◁ Have the tool checked and, if necessary, repaired by Hilti Service.
Note
Dirt and residues build up in the tool under normal operating conditions and functional parts are
also subject to wear.
Carry out regular inspections and servicing. Servicing must be carried out after 30,000 fasteners
have been driven.
Clean the tool after every 2,500 - 3,000 fastenings. The fastener counter shows how many fasteners
have been driven since the cleaning indicator was last reset. One bar stands for 500 fasteners.
Check the piston and the buffer daily when the tool is subjected to intensive use, or at the very
least, before the end of the recommended regular cleaning interval of 2,500 - 3,000 fastenings.
The inspections, service intervals and cleaning intervals are based on typical tool use. If you find
that the tool is not functioning correctly before a scheduled interval is reached, service the tool
immediately.
6 Care and maintenance
6.1 Care of the tool
WARNING
Cleaning Pay attention to the following points when cleaning the tool:
▶ Do not clean with a spray system or pressure jet washer.
▶ Do not permit foreign objects to enter the interior of the tool.