17. Other functions
88
Service menu settings:
Burner settings
Startup
Heating time
Startup fuel batch
Flame detection
Startup blow-in
Startup time
Operation
Maximum burner power
Maximum FL burner power
FL burner minimum power
Blow-in settings:
- Blow-in nominal power
- Oxygen nominal power*
- Blow-in intermediate power
- Oxygen intermediate power*
- Blow-in minimum power
- Oxygen minimum power*
OPERATION mode cycle time
Monitoring time
Feeder output
Fuel calorific value
Operation with oxygen sensor*
Cleaning
Linear actuator extended
Linear actuator retracted
Ash removal time*
Heat exchanger cleaning time*
Variable grate geometry
Control
Actuator at nominal power
Actuator at minimum power
Cleaning - interval
Cleaning - movement
Grate - wood
Maximum startup time
Blow-in operation - monitoring
Blow-in idle time - monitoring
No fuel detection time
Heating and ventilation
Storage bin settings
Storage bin volume
Fuel level sensor
Minimum fuel level
Feeder
Output test time
Feeder output test
Fuel weight
* niedostępne jeśli nie podłączono odpowiedniego czujnika, modułu
dodatkowego lub parametr jest ukryty.
Boiler settings
OPERATION MODE
Return protection
- Return protection 4D
- Return hysteresis
- Minimum return temperature
- Close valve
Maximum boiler temperature
Select thermostat
Boiler hysteresis
ON / OFF
Pump disabled by thermostat
OFF
OFF
Platinum Bio ecoMAX 860P User Manual – EN 07.22
ON / OFF