To order optional wiring kits, contact Customer Service.
Limited access application
CAUTION: The fan must operate on a dedicated
circuit with a dedicated neutral. Failure to install
the fan on a dedicated circuit can cause the fan to
operate improperly.
Illustrated on the right is a typical lighting circuit with
one basic light switch. The fan operational critical red
conductor or "traveler" conductor is absent. For Isis
applications in which installing a 3-wire plus ground circuit
(black, white, and red) is impractical or impossible, an
optional limited access fan controller can be installed to
eliminate the required red traveler conductor between the
controller and the fan, allowing the utilization of the existing
2-wire plus ground circuit (black and white) shown on the
right.
Note: This scenario is common in residences in which only
a light circuit was previously installed.
Power Supply
See page 27 for
specifications
and wire colors.
Alternative Wiring Methods
Power Supply
See page 27 for
specifications
and wire colors.
fan
®
Basic 2-Wire (Plus Ground) Single Fan Application
Fan Speed
Controller
Companion Module
Mounted in existing
switch box on wall
GREEN
WHITE
BLACK
WWW.BIGASSFANS.COM
©2014 DELTA T LLC
Isis
®
Typical Lighting Circuit
Basic Light Switch
Existing Switch
Box on Wall
GREEN
WHITE
BLACK
Fan Speed
Controler Remote
Fixture Module
Mounted local to fan
in ceiling junction box
Status LED
ALL RIGHTS RESERVED
GREEN
WHITE
BLACK
RED
33