USER'S MANUAL. RP-250
4.2.2.5 8-pilots generator operation mode
The equipment can generate up to eight different signal pilots simultaneously.
Select the pilot number trough the instrument configuration mode: CONFIG [F1]
(see section "4.2.1 Configuration of internal parameters (CONFIG)") and select PILOTS
option in the configuration menu, next by means of the navigation buttons [7] select the
8-pilots mode.
Now, it is possible to set the pilot signals in the following frequency ranges:
8-PILOTS MODE
Pilot 1:
from 5.00
Pilot 2:
from 120.01
Pilot 3:
from 350.01
Pilot 4:
from 650.01
Pilot 5:
from 900.01
Pilot 6:
from 1250.01
Pilot 7:
from 1750.01
Pilot 8:
from 2050.01
4.2.2.6 6-pilots generator operation mode
The equipment can generate six different pilot signals simultaneously. The
operation in this mode is similar to the previously described for the 8-pilots mode. (see
section "4.2.2.5 8-pilots generator operation mode").
The RP-250, allows to set the six pilot signals in the following frequency ranges:
6-PILOTS MODE
Pilot 1:
from 5.00
Pilot 2:
from 350.01
Pilot 3:
from 650.01
Pilot 4:
from 900.01
Pilot 5:
from 1250.01
Pilot 6:
from 1750.01
4.3 Connecting to a Computer.
The RP-250 permits the connection to a PC for data transfer, by means of the
connection cable model: CC-RP250.
Do not connect any cable other than that supplied by the manufacturer,
otherwise serious damage may be caused to the equipment.
Page 23
to
120.00 MHz
to
350.00 MHz
to
650.00 MHz
to
900.00 MHz
to
1250.00 MHz
to
1750.00 MHz
to
2050.00 MHz
to
2500.00 MHz
to
350.00 MHz
to
650.00 MHz
to
900.00 MHz
to
1250.00 MHz
to
1750.00 MHz
to
2500.00 MHz
03-2007