Graf KLARO Easy Notice D'installation page 37

Système de traitement dans une installation multi-cuves assainissement carat s
Masquer les pouces Voir aussi pour KLARO Easy:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The locking height of the lifters depends on the system type and can be found in the table shown below.
Tank size
A
mm
2x 2,700L
400
2x 3,750L
400
2x 4,800L
400
2x 6,500L
400
A - use of mini tank dome
A* - use of maxi tank dome
The clips of the PVC pipe clamps are then closed.
5.5
Installation of the crossbar
To fix the crossbar in the tank, holes are drilled through the opposing ribs in the access area using an 8
mm drill. The correct separation distance can be marked out with the aid of the crossbar.
The crossbar is then fixed into these holes using the M8 screws (2x M8x45), nuts (2x) and washers (4x).
The crossbar is then used to receive the holding plate from section 5.1.
5. Installation of the setting-up kit
A*
B
mm
mm
500
455
500
645
500
880
500
1155
35 / 92
A
B
B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Klaro e

Table des Matières