IMMEDIATE AUTOMATIC
MESSAGE
DISPLAYED
/ FAULT
Production pH regulation
DETECTED
No
Yes
STOP
Series of 5 unsuccessful
Yes
attempts to correct the
Insufficient quantity of
Yes
POSSIBLE CAUSE
pH
water
Zero salt level
CHECKS AND REMEDIES
Ensure the pH corrector
container is not empty.
Check the condition of
the :
- filter with ballast.
- semi-rigid pipes.
- peristaltic pump.
- injection connector.
Carry out a manual
injection.
Check that :
- the peristaltic pump is
working properly.
- the pH corrector is
injected correctly.
Check the settings in
the «
»,
«
and «
menus.
Carry out a calibration
of the pH probe.
Check that :
- the filtration pump is
working correctly.
- the pipe at the level
of the salt sensor is
completely filled with
water.
Top up the water if
necessary.
Check the salt level
manually with a recent
test kit.
Top up with salt if
necessary, so as to
obtain a salt level of 5
3
3
kg/m
(or 2.5 kg/m
for
Low Salt equipment).
OPTION TO
DEACTIVATE
VIA THE MENU
«
»
Yes
»
»
Yes
19