2.6.21. pH probe calibration

The original pH probe is already calibrated. It is therefore not necessary to carry out calibration of the pH probe
when putting the equipment into service for the first time.
I
However, it is imperative to carry out a calibration at the beginning of each season when returning to
service, and after each probe replacement.
1) Open the pH 7 and pH 10 calibration solutions (use only single-use calibration solutions).
2) Turn off the filtration (and therefore the electronics unit).
3) If the probe is already installed :
a) Take the probe out of the measuring chamber, without disconnecting the probe.
b) Close the housing of the probe in the measuring chamber using the cap provided for this purpose.
If the probe is not already installed :
Connect the probe to the electronics unit.
4) Turn on the electronics unit.
5) Go to the «
6) Navigate through the menus following the below instructions :
OK
OK
(Wait a few seconds)
or
OK
(Wait a few seconds)
or

2.6.22. Activation/deactivation of pH regulation

Menu
» menu.
Insert the probe into the pH 7 calibration solution, then wait a few minutes.
Do not touch the probe.
Carry out the navigation again with the above instructions, several times if
necessary. If calibration still fails, replace the probe then carry out another
calibration.
a) Rinse the probe under running water, then leave to drip-dry it without wiping it.
b) Insert the probe into the pH 10 solution, then wait for a few minutes.
Do not touch the probe.
a) Rinse the probe under running water, then leave to drip-dry it without wiping it.
b) (Re)install the probe in the measuring chamber.
Carry out the navigation again with the above instructions, several times if
necessary. If calibration still fails, replace the probe then carry out another
calibration.
Possible settings
ON (to activate)
OFF (to disable)
Default setting
ON