Change the bag when the one in place is
full. Frequency will depend on use of the
unit. For the GX series,the integrated monitor
will indicate when to change the bag. These
indications are provided by an electronic
timing board, only as a reference guide.
1. To access the bag, unlatch the two
clips and remove the dust receptacle
(figure 16).
2. Remove the used bag and seal bag opening
(adhesive seal provided on each bag).
Discard used bag.
3. Install the new bag, ensuring the tabs on
the bag adaptor are aligned with the slots
in the bag collar (figure 17).
4. Ensure adequate sealing by inserting bag
as far as retention ring (figure 18 - A).
Rotate bag 20° (figure 18 - B) to ensure
tabs on bag adaptor are no longer aligned
with the slots in the bag collar.
5. Replace dust receptacle and seal by
latching both clips.
Use only genuine Cyclo Vac replacement bags.
Failure to do so could void the warranty on
your vacuum unit.
Part numbers :
TDSAC33C : GS 210, 211, 310, 311 - GX 310, 311
TDSAC83C : GS 710, 711 - GX 710, 711, 2010, 2011, 5010, 5011, 7010, 7011

Ultra-Fresh* Permanent Filter

This drum-shaped filter requires no maintenance. It will be checked by the service
center when you have the vacuum power unit inspected, after approximately
500 hours of use (around 10 years, depending on use).
* Ultra-Fresh is a trademark of Thomson Research Associates