- View (viev)
allows to visualise the stored devices using the menu scrolling keys.
WARNING: after completing the network scanning, use the "View" option on
the menu to check, that ALL the connected devices have been acquired.
6.8) DIAGNOSTICS AND MONITORING
The display on the NETTUNO B panel shows some useful information, both
during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating which
device needs to be checked:
STRT = START
input activation
STOP = STOP input activation
PED = PEDESTRIAN access input activation
OPEN= hold-to-run START/OPEN control input activation
CLS = hold-to-run PEDESTRIAN/CLOSE control input activation
PHOT = PHOT input activation
ENET = FAST NET failure
TER = Test of safety devices unsuccessful.
In the case where an obstacle is found, the NETTUNO B panel stops the
door and activates a reverse manoeuvre; at the same time the display shows
the "AMP" message.
If the communication between a FAST NET device and the control unit
is interrupted, the corresponding device that has been damaged will be
displayed.
Monitoring:
During the opening and closing phases, the display shows four digits sepa-
rated by a dot, for example 35. 4 0. The digits are constantly updated during
the manoeuvre, and represent the maximum torque reached by motor 1
(35) and motor 2 (40).
These values allow the torque setting to be corrected.
If the maximum torque value reached during the manoeuvre gets sensibly
close to the value set in the parameter menu, malfunctions may occur in the
future following wear or slight door deformation.
It is therefore advisable to check the maximum torque reached during some
of the manoeuvres carried out in the course of installation, and if necessary
set a value about 15-20 percent points higher in the parameter menu.
7) STATISTICS
Having connected the
Universal palmtop programmer
enter the CONTROL UNIT / STATISTICS menu and scroll the screenful
showing the statistical parameters:
-
Board microprocessor software version.
-
Number of cycles carried out. If motors are replaced, count the number
of manoeuvres carried out up to that time.
-
Number of cycles carried out from the latest maintenance operation.
It is automatically set to zero after each self-diagnosis or parameter writing.
-
Date of latest maintenance operation. To be updated manually from the
appropriate menu "Update maintenance date".
-
Installation description. 16 characters can be entered for installation
identification.
8) INTEGRATED RECEIVER TEChNICAL SPECIFICATION
Receiver output channels:
-
output channel 1, if activated, controls a START command.
-
output channel 2, if activated, controls the excitation of the 2nd radio
channel relay for 1s.
A radio receiver module can be introduced into the JP11 connector; in
this case an antenna should be connected to the 1-2 terminals. Likewise,
a radio module can be fitted to the NET-LAMP but this configuration does
not require an antenna (which is already supplied with the NET-LAMP) and
guarantees a wider range.
Transmitter versions which can be used:
all Rolling Code transmitters compatible with
9) RECEIVER CONFIGURATION
The FAST NET receiver combines characteristics of utmost safety in copy-
ing variable code (rolling code) coding with the convenience of carrying out
transmitter "cloning" operations thanks to an exclusive system.
Cloning a transmitter means creating a transmitter which can be automatically
included within the list of the transmitters memorised in the receiver, either
as an addition or as a replacement of a particular transmitter.
Cloning by replacement is used to create a new transmitter which takes
the place of the one previously memorised in the receiver; in this way a
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
specific transmitter can be removed from the memory and will no longer
be usable.
Therefore it will be possible to remotely program a large number of additional
transmitters or, for example, replacement transmitters for those which have
been lost, without making changes directly to the receiver.
When coding safety is not a decisive factor, the on-board receiver allows
you to carry out fixed-code additional cloning which, although abandoning
the variable code, provides a high number of coding combinations, there-
fore keeping it possible to "copy" any transmitter which has already been
programmed.
PROGRAMMING
Transmitter storage can be carried out in manual mode or by means of
the
database to be managed through the Eedbase software.
In this second case, receiver programming takes place through the connection
of
the UNIFLAT and UNIDA accessories as indicated in Fig. 4.
10) MANUAL PROGRAMMING
In the case of standard installations where advanced functions are not
required, you can proceed to manual storage of the transmitters, making
reference to fig. B for basic programming.
-
-
IMPORTANT NOTE: ATTACh ThE ADh ESIVE KEY LABEL TO ThE FIRST
MEMORISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the key
code to the receiver; this code is necessary in order to carry out subsequent
cloning of the radio transmitters.
to the control unit,
11) RADIO-TRANSMITTER CLONING
Rolling-code cloning / Fixed-code cloning
Make reference to the universal palmtop programmer Instructions and the
CLONIX Programming Guide.
11.1) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the Universal palmtop programmer Instructions and the
CLONIX Programming Guide.
12) SCRAPPING
Warning: This operation should only be carried out by qualified person-
nel. Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out by
type (electrical components, copper, aluminium, plastic etc.).
13) DISMANTLING
Warning: This operation should only be carried out by qualified person-
nel. When the control unit is disassembled to be reassembled on another
site, proceed as follows:
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
.
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
universal palmtop programmer
universal palmtop programmer
If you wish the transmitter to activate output 1 (START) by means of key1,
key2, key3 or key4, enter the transmitter in menu "Start key", as in fig. B.
If you wish the transmitter to activate output 2 (2nd radio channel relay)
by means of key1, key2, key3 or key4, enter the transmitter in menu "2nd
ch. key", as in fig. B.
Note: Hidden key P1 appears differently depending on the transmitter
model.
For transmitters with hidden key, press hidden key P1 (fig. B1). For transmit-
ters without hidden key, the key P1 function corresponds to simultaneously
pressing the 4 transmitter keys or, after opening the battery compartment,
bridging the two P1 points by means of a screwdriver (fig. B2).
Disconnect the power supply and the entire electrical installation.
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
ENGLISh
which allows the complete installation
to the NETTUNO B control panel, using
NETTUNO B - Ver. 05 - 15