EFFLUENT & SEWAGE APPLICATIONS - UP TO 3/4" & 2" SOLIDS HANDLING CAPABILITY
These pumps are for use in effl uent or raw sewage ap-
plications where the total head required (including pipe
friction losses) does not exceed the pump's maximum
capability. Sewage type pumps can be used in raw
sewage or effl uent applications.
For future reference, keep an accurate record of your installation. Be sure to record the installation data in the area
provided below.
Purchased from:
Phone No. (
)
Pump Model No.
Pump Serial No.
Date of Installation:
Safety, Regulatory and Electrical Warnings....................................................................................... Throughout manual
Application ............................................................................................................................................................. Page 2
Installation Records and Table of Contents ........................................................................................................... Page 2
Installation Information and Typical Installation Drawings ..................................................................... Pages 2, 3, 4 & 5
Start Up and Operational Check............................................................................................................................ Page 6
Safety Tips and Maintenance ................................................................................................................................ Page 6
Troubleshooting ..................................................................................................................................................... Page 7
Warranty ................................................................................................................................................................ Page 8
INSTALLATION RECORD
TABLE OF CONTENTS
Solids
Pump
Pump
Handling
Type
Model
(inches) H.P. RPM
Effl uent
RL31ESA
11/16''
Sewage
RL52SA
2''
RL52SVX
2''
Additionally, the maximum solids size, as shown in
Fig.1, must not be exceeded.
Installation by:
Phone No. (
Pump Tank or Basin Size:
Discharge Pipe size:
Discharge Elevation:
PERFORMANCE
Total Head in Feet
5
10
15
Capacities in U.S. GPM
1/3
1750 105
90
70
1/2
1750 135
90
47
1/2
1750 112
80
40
2
)
20
25
Shut-Off
Head (ft).
45
15
28
14
23
18
Capacity
Inches
Feet

Publicité