4.1
Disassembling the pump (only for ROSOLAR PUMP PLUS)
Disconnect line connections.
Unscrew bolts on the pump side.
Remove cover and side disc.
Pull housing with impeller and rear side
disc off the shaft.
4.2
Replacing components (only for ROSOLAR PUMP PLUS)
Impeller
To change the impeller we recommend to
use a special tool (s. page 62).
Push impeller out of the casing.
Insert a new impeller. Observe direction of impeller wings!
Lateral discs
Turn around or replace.
Seals
Replace O-rings and push firmly into the recesses.
Replacing shaft gasket:
Remove retaining ring with suitable pliers.
Push out bearing and shaft gasket.
Push in new shaft gasket and bearing.
Insert retaining rings.
4.3
Assembling the pump (only for ROSOLAR PUMP PLUS)
Assembly of the pump is the reverse of
disassembly:
Connect lateral disc with punched hole to
the rear of the casing.
Push casing with impeller and second
lateral disc onto the shaft.
Insert and tighten bolts.
Attach lines.
The lateral discs and O-rings must lie precisely in the recesses to ensure that the O-rings
are not pinched.
12
intake
ENGLISH
outlet