Regulate the minimal position of the tap with the burner burning, Turn the tab to the minimal position, take
off the tap handle and then fasten or unfasten the frontal screw of the tap (at the left of the tap) in order to
adjust the flame size to the minimum. Be careful not to turn off the flame and allow the thermocouple to
receive heat (otherwise it will close the tap). After defining the minimal position of the tap, wait ca, 2
minutes to make sure the flame keeps burning.
LINE GGP6 BURNER
In order to replace the injector in this type of burner, you have to turn the equipment upside down. In order to
take out the burner, push it a bit to the back of the equipment and this loosens the burner from the aluminium
part. The injector becomes accessible and it can be replaced. Use an adequate nut driver to take it out.
Attention: Keep in mind the relation between the diameter of the injector's hole and the type of gas.
LINE VERTICAL BURNER
In order to replace the injector in the vertical burner, loosen the screw that fixes the injector's support. Take
out the old injector and replace it with the new one (of another gas type). The position of the injector's
support influences the entrance of air, thus regulating the gas flame. Keep this in mind when you adjust the
injector's support position upwards or downwards.
6. MAINTENANCE AND SERVICING
(ONLY FOR QUALIFIED TECHNICIANS)
The following steps should be taken in order to perform all kinds of servicing operations (cleaning or
replacement of burners, changing the type of gas and other operations):
-
Close the gas supply tap;
-
Disconnect the supply hose of the machine;
-
Turn the machine upside down;
-
Pull out the tap knobs;
-
Through the inner part, using a screwdriver, unfasten the two screws that fix the frontal part of
the device;
-
Unfasten the screw nut that connects the gas hose to the injector;
-
Unfasten the upper screw that secures the burner, This operation will simultaneously unfasten
the screw nut that regulates the air.
6.1. LINE GGP15 BURNER
With this type of burner, follow these instructions:
It is now possible to replace the gas injector with the one supplied with the machine, suitable for gas
changes, You must keep in mind that when loosening the injector, the nut that regulates the air that goes in
the burner will also become loose.
When installing the new injector, the nut that regulates the air must be fastened, There's no need to fasten the
upper screw that secures the burner, seeing as it should be fastened when the burner is being tested and after
having regulated the passage of air, Please remember that the grill plate should be tested in its working
position.
In this position, one can reach the upper fixing screw of the burner (which simultaneously fixes the nut that
regulates the air) through the hole in the upper part of the taps.
When cleaning or replacing the burner, after loosening the nut that connects the gas hose to the injector,
loosen the nut that connects the thermopar to the gas tap and disconnect the cable terminal that feeds the
lighter, Unfasten the two frontal fixing screws, which completely loosen the burner.
Always keep in mind that after performing any change in the type of gas, it is necessary to regulate the air as
well as the minimum power of the tap. To regulate the air unfasten the upper screw of the burner and turn the
air regulation nut (clockWise = less air). After adjusting the nut, fasten the screw that fixes the burner,
Fastening this screw also attaches the air regulation nut, which becomes fastened.