Screw connections
If connections leak, there is a danger of explosion, fire or suffocation!
Gas may escape if the product is turned.
Do not turn the product after it has been installed and the connections have been
tightened.
Tighten connections only when they are not pressurised.
The gaskets at the inlet connections (if provided) must be replaced when re-assembling!
Make sure that the gaskets sit properly in the mounting and that the screws are tightened.
Connecting and installing hoses assemblies
Connect hoses so that mechanical, thermal and chemical stresses are avoided:
 mechanical stress: e.g. do not pull the hose assembly over sharp edges
 thermal effect: e.g. avoid open flames, radiant heat
 chemical effect: e.g. avoid grease, oil, caustic substances
Install hose assemblies so that they are not under tension (no bending and tensile strains
or torsion).
Install hose assemblies so that their connections cannot loosen unintentionally.
Connections to the pressure regulator with 90° outlet prevent the hose assembly from
being kinked.
Observe the applicable national installation regulations for LPG systems.
To connect to the gas cylinders, suitable high pressure hose assemblies with
excess flow device (e.g. 2x Caramatic ConnectDrive – not included in the delivery) must be
used!
Mounting material
Excessive force may damage the product.
This can cause leaky connections.
Attachments must be dimensioned and connected to the vehicle wall so that this provides
a secure hold on the one hand and enables forces to be deflected safely on the other.
Forces should not affect on the product.

LEAK CHECK

The liquefied gas unit must be checked for leaks by an expert* before the first start-up, during
checking and maintenance work, before the re-start and after important changes and repair
work. See USER QUALIFICATION!
Observe the applicable national installation regulations for LPG systems.
Simplified leak check
Check for leaks every time you replace a cylinder or if the system has not been used for some
time.
1. Close the cylinder valve on the operating side.
2. Open the cylinder valve on the spare side.
3. The visual indicator type AUV changes from GREEN to RED = spare.
4. Close the open cylinder valve on the spare side.
Observe EN 1949.