Backwash
BACKWASH
BACKWASH
SPEED
BACKWASH PERIOD
RINSE PERIOD
BACKWASH
BACKWASH PERIOD
RINSE PERIOD
INTERVAL
STARTING TIME
06|2017
The following settings can be made for
FILTER
backwashing:
ON
80 %
Backwash on/off, speed 35 % - 100 %,
1 MIN
backwash period, rinse period, interval
30 SEC
1 - 21 days, starting time.
WG27.50.067-2-P
If the pump is currently in backwash
FILTER
mode, this is indicated in the operating
1 MIN
30 SEC
mode display by the text "Backwash".
7 DAYS
14:00
The backwash period specifies the
duration of the backwash process which
WG27.50.068-2-P
consists of the speed and duration of
the backwash valve setting. The
backwash valve is initiated by realy 11
of the pump control unit.
The rinse period specifies the duration
of the rinse process which consists of
the speed and duration of the rinsing
valve setting. The rinsing valve is
initiated by relay 12 of the pump control
unit.
The safety enable contacts S1 or S2 of
the motor control unit are used to stop
the pump when the backwash valve
changes position.
For wiring diagrams and connection
examples refer to page 40.