10 Supplement; 10.1 Technical Data - SICK LFC Manuel De Mise En Service

Transistor (pnp)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10 Supplement

10.1 Technical data

Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
Materials and weights
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Sensor tip
Ʋ Device seal - Standard version
Ʋ Device seal - Hygienic version
Ʋ Process seal
Ʋ Process fittings
Materials, non-wetted parts
Ʋ Housing
Ʋ Seal plug
Weight
General data
Process fittings
Ʋ Pipe thread, cylindrical (DIN 3852-A)
Ʋ Pipe thread, conical (ASME B1.20.1)
Ʋ Threaded adapter (ISO 228-1)
Threaded and hygienic adapter
Ʋ Standard hygienic adapter
Max. torque - process fitting
Ʋ Thread G½, ½ NPT
Ʋ Thread G¾, ¾ NPT
Ʋ Thread G1, 1 NPT
Ʋ Hygienic adapter
Surface quality
Measurement accuracy
Hysteresis
Switching delay
Ambient conditions
Ambient temperature on the housing
Storage and transport temperature
LFC • Transistor (PNP)
PEEK, polished
FKM
EPDM
Klingersil C-4400
316L
316L and plastic (Valox)
NBR
approx. 200 g (0.441 lbs)
G½, G¾, G1, M 24 x 1.5
½ NPT, ¾ NPT, 1 NPT
G½, G1
50 Nm (37 lbf ft)
75 Nm (55 lbf ft)
100 Nm (73 lbf ft)
20 Nm (15 lbf ft)
R
< 0.76 µm (3.00
in)
-5
a
approx. 1 mm (0.04 in)
approx. 500 ms (on/off)
-40 ... +70 °C (-40 ... +158 °F)
-40 ... +80 °C (-40 ... +176 °F)