Built-in Construction Details
Standard layout for non-combustible cavity
IMPORTANT!
If installing the grill into a non-combustible enclosure, all combustible construction must still be
outside the 18" (457mm) clearance zone. If your island is made of stucco over the top of wooden
studs, the wood can not be inside the 18 inch clearance zone to combustible, even though the stucco
is what is touching the grill area.
G
Note: vents are to be located at the left,
right and rear of the enclosure. Minimum
size of all vents is 10x10" (645mm x 645mm)
CAVITY DIMENSIONS
A Maximum height of enclosure shell
B Depth of enclosure shell
C Minimum depth for hood swing
D Width of enclosure cavity
E Height of enclosure cavity
f Depth to gas supply opening
G Height to base of vents
H Height of opening for access doors/drawers
I Width of opening for access doors/drawers
INSTALLATION
D
F
E
I
H
FIG. 05
C
Note: 4x4" (102 x 102mm)
opening for gas supply line
B
A
Note: the cut-out of each
corner should be a 90°angle
in order for the access doors/
drawers to fit properly.
BE1-48R
Inches (mm)
35 1/2" (902)
22 3/4" (578)
3 3/4" (95)
45 3/4" (1162)
10 1/8" (257)
18 1/2" (464)
1" (25)
20" (508)
46" (1168)
EN
BE1-36R
Inches (mm)
35 1/2" (902)
22 3/4" (578)
3 3/4" (95)
34 1/2" (876)
10 1/8" (257)
18 1/2" (464)
1" (25)
20" (508)
34" (864)
13