Built-In Construction Details - Fisher & Paykel DCS BGC48-BQAR Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
BUILT–IN CONSTRUCTION DETAILS
34,93 cm/
13 3/4 "
5,08 cm/
2 "
Standard layout for non-combustible enclosure:
64,5 cm
2
/10
"2
Min. ventilation
on the back side
64,5 cm
2
/10
"2
min
ventilation
left
25,72 cm/
10 1/8 "
90.17 cm/
35.5 " max
2,54 cm/1 " min.
Layout for insulated jacket only - combustible enclosure:
64,5 cm
2
/10
"2
Min. ventilation
on the back side
64,5 cm
2
/10
"2
min
ventilation
left
28,26 cm/
11 1/8 "
90.17 cm/
35.5 " max
2,54 cm/1 " min.
grill
exhaust
7,6 cm/3 " (to non-combustible
construction / minimum
lid clearance)
45,7cm / 18 " (to combustible
construction)
Bottom of
support flange
24,5 cm/10 "
55,88 cm/22 "
3,81cm/1 1/2 "
64,77 cm/25 1/2 "
NOTE: If using a backguard
apron or rear wall, locate
48" Models =
116,2 cm/45 3/4 "
36" Models =
electrical service on the
87,6 cm/34 1/2 "
right hand side for rotisserie
46,99 cm/
18 1/2 "
50,8 cm/20 "
48" Models
= 116,8 cm/46 "
36" Models
= 86,36 cm/34 "
48" Models =
131,13 cm/51 5/8 "
36" Models =
102,9 cm/40 1/2 "
FIG. 05
46,50 cm/
18 1/4 "
50,8 cm/20 "
48" Models =
116,8 cm/46 "
36" Models =
86,36 cm/34 "
9,5cm / 3 3/4" Min. for Lid
57,79 cm/22 3/4 "
10,16 x 10,16cm
(4 x 4 ") opening
for gas supply
line
64,5 cm
2
/10
"2
min.
ventilation
on the right
opening for access doors/
drawers (see Fig. 06 & 07 for ordering information)
NOTE: If using a backguard
apron or rear wall, locate
electrical service on the
right hand side for rotisserie
18 3/4" (47,6cm) Min. for Lid
60,33 cm/23 3/4 "
10,16 x 10,16cm
(4 x 4 ") opening for gas supply line
8,89 cm/3 1/2 "
25,4 cm
2
/10
"2
min.
ventilation
on the right
opening for access doors/
drawers (see Fig. 06 & 07 for ordering information)
12
WARNING!
If installing the grill into a
non-combustible enclosure,
all combustible construction
must still be outside the 18
inch clearance zone. If your
island is made of stucco over
the top of wooden studs, the
wood can not be inside the
18 inch clearance zone to
combustible, even though
the stucco is what is
touching the grill area.
INSULATED JACKET
Size
Part No.
36
70167
48
70172
FIG. 05

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Dcs bgc48-bqrDcs bgc36-bqar

Table des Matières