Baxi 45 HTE Notice D'emploi Destinée À L'usager Et À L'installateur page 52

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12. making the electrical connections
Electrical safety of the appliance is only guaranteed by correct grounding, in accordance with the rules in for-
ce.
Connect the boiler to a 230V monophase + ground power supply by means of the three-pin cable supplied with
it and make sure you connect polarities correctly.
Use a double-pole switch with a contact separation of at least 3mm in both poles.
In case you replace the power supply cable fit a HAR H05 VV-F' 3x­0.75mm
cable with an 8mm diameter
2
max­.
IMPORTANT: Check that the overall current drawn by accessories connected to the appliance is less
than 2 A. If the value is greater, a relay must be wired between the boiler control circuit board and the
accessories drawing the higher current.
Cover
Terminal Block
Terminal Block
Cover
Facia panel
Terminal Block
Figure 8
12.1 terminal blocks access
• Cut off power to the boiler with the two-pole switch.
• Remove the top facia panel cover (which is held by magnets).
• Unscrew the two screws holding the facia panel in place.
• Swing the facia panel forwards.
Main terminal block M1
• Remove the clip-on cover from terminal strip M1.
• The main terminal block incorporates a fast blow 3.15 A fuse (figure 8). Remove the black fuse holder to
check and/or replace the fuse.
Terminal block M2
• Unscrew the fix­ing screw and remove the cover from terminal block M2.
Terminal block M3
• Unscrew the fix­ing screws and remove the main cover.
IstructIons pErtaInIng to thE InstallEr
912.403.1 - IE
52

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

65 hte85 hte100 hte120 hte150 hte

Table des Matières